Baumfolder BAUM1620 Gapset Calibration User Manual
Page 3

3
Factory Calibration of 1620 Gapsets & Field/Service Fold Roll Replacement:
1. The proper fold roll gapset calibration sequence is as follows:
a) #1
fold
roll
to
main
fold
roll
b) #2
fold
roll
to
main
fold
roll
c) #3
fold
roll
to
#2
fold
roll
d) #4
fold
roll
to
#3
fold
roll
e) #5
fold
roll
to
#4
fold
roll
This
sequence
of
setting
the
fold
rolls
must
be
followed,
as
not
doing
so
may
result
in
improper
calibration
of
the
fold
rolls
causing
inaccurate/crooked
folds.
2. Ensure that there is an equal gap on both the operator and non-‐operator sides between all fold
rolls.
This
gap
only
needs
to
be
large
enough
to
allow
a
single
sheet
thickness
of
20#
bond
paper
to
freely
be
slid
between
the
rolls.
-‐ To
increase
the
gap
between
the
fold
rolls,
turn
the
gapset
knob
clockwise
-‐ To
decrease
the
gap
between
the
fold
rolls,
turn
the
gapset
knob
counter-‐clockwise.
3. Place (1) 1” wide strip of 20# bond paper towards the outer portion of the main and #1 fold rolls
ensuring
that
the
paper
is
making
full
contact
with
the
urethane
bands
of
the
fold
rolls.
As
you
place
each
strip
of
paper
into
the
proper
fold
rolls
that
you
are
calibrating
the
gapsets
for,
it
is
helpful
to
turn
the
gapset
knob
counter-‐clockwise
until
the
strip
of
paper
is
being
held
lightly
by
the
fold
rolls.
-‐ While placing the strip of paper on the operator side of the fold rolls, adjust the #1
gapset
knob
on
the
operator
side.
-‐ While placing the strip of paper on the non-‐operator side of the fold rolls, adjust the #1
gapset knob on the non-‐operator side.