7. Place filter in furnace.

8. Replace blower access panel and main furnace door.

9. Turn on electrical supply to furnace.

NOTE:

If the filter has cross-mesh binding, the binding must face

the blower. If the filter has an air direction arrow, the arrow must
point toward the blower.

II.

BLOWER MOTOR AND WHEEL MAINTENANCE

To ensure long life, economy, and high efficiency, clean accumu-
lated dirt and grease from blower wheel and motor annually.

The inducer and blower motors are pre-lubricated and require no
additional lubrication. These motors can be identified by the
absence of oil ports on each end of the motor.

The following items should be performed by a qualified service
technician.

Clean blower motor and wheel as follows:

1. Turn off electrical supply to furnace.

2. Remove main furnace door and blower access panel.

3. Disconnect wires.

All factory wires can be left connected, but field thermostat
connections may need to be disconnected depending on
their length and routing.

4. Position control box, transformer, and door switch assembly

to right side of furnace casing.

5. If condensate trap is located in left- or right-hand side of

furnace casing, proceed to item 6, otherwise remove trap
and tubing as described below.

a. Disconnect field drain connection from condensate trap.

b. Disconnect drain and relief port tubes from condensate

trap.

c. Remove condensate trap from blower shelf.

6. Remove screws securing blower assembly to blower shelf

and slide blower assembly out of furnace.

7. Clean blower wheel and motor by using a vacuum with soft

brush attachment. Be careful not to disturb balance weights
(clips) on blower wheel vanes. Do not bend wheel or blades
as balance will be affected.

8. If greasy residue is present on blower wheel, remove wheel

from the blower housing and wash it with an appropriate
degreaser. To remove wheel:

a. Mark blower wheel location on shaft before disassembly

to ensure proper reassembly.

b. Loosen setscrew holding blower wheel on motor shaft.

NOTE:

Mark blower mounting arms and blower housing so each

arm is positioned at the same hole location during reassembly.

c. Mark blower wheel orientation and cutoff plate location

to ensure proper reassembly.

d. Remove screws securing cutoff plate and remove cutoff

plate from housing.

e. Remove bolts holding motor mounts to blower housing

and slide motor and mounts out of housing. Disconnect
capacitor and ground wire attached to blower housing
before removing motor.

f. Remove blower wheel from housing.

g. Clean wheel per instructions on degreaser cleaner.

9. Reassemble motor and blower wheel by reversing items 8b

through 8f. Ensure wheel is positioned for proper rotation.
Be sure to reattach ground wire.

10. Reinstall blower assembly in furnace.

11. Reinstall condensate trap and tubing if previously removed.

a. Reinstall condensate trap in hole in blower shelf.

b. Connect condensate trap drain tubes. See Fig. 8 or tubing

diagram on main furnace door for proper tube location.

(1.) Connect 1 tube (blue or blue and white striped)

from collector box.

(2.) Connect 1 tube (violet or unmarked) from inducer

housing.

(3.) Connect 1 tube (relief port, green or pink) from

collector box.

c. Connect field drain to condensate trap.

NOTE:

Ensure tubes are not kinked or pinched, as this will affect

operation.

12. Reinstall control box, transformer, and door switch assem-

bly on blower shelf.

13. Reconnect wires.

Refer to furnace wiring diagram, and connect thermostat
leads if previously disconnected. (See Fig. 16.)

NOTE:

Refer to Table 1 for motor speed lead relocation if leads

were not identified before disconnection.

Fig. 3—Bottom Filter Arrangement

A93046

WASHABLE
FILTER

FILTER
SUPPORT

FILTER
RETAINER

Fig. 4—Filter Installed for Side Inlet

A93045

FILTER
RETAINER

WASHABLE

FILTER