Removal and Replacement::
1. Remove the wires from the switch terminals.
2. Compress the clips inside the autofill box and

gently push the switch through the opening

3. Push the new switch into the opening and spread

the clips to hold switch in the autofill box.

4. Refer to Fig 7 when reconnecting the wires.

P1522

FIG. 7 MAIN ON/OFF SWITCH TERMINALS

BLK from Fuse Holder

BLK to Pump Switch #2

MAIN ON/OFF SWITCH

FIG. 6 MAIN ON/OFF SWITCH

P1561

Location:

The main ON/OFF switch is located on the

lower right front of the autofill box just above the power
cord.

Test Procedure:
1. Disconnect the dispenser from the power source.
2. Disconnect the black wire from the fuse holder to

the main ON/OFF switch. Disconnect the white
wire from pump #1.

3. Check for voltage across the black wires removed

from the switch and the white wire removed from
pump #1. Connect the dispenser to the power
source. The indication must be:
a) 120 volts ac for 2 wire 120 volt models.
b) 200 to 240 volts ac for two wire 200 or 240 volt
models.

4. Disconnect the dispenser from the power source.

1



2

1



2

FL

A

FLA

VO

R

OR

INP

UT

INPUT

MIX

ED

PR

MIXED PR

OD

UC

T O

UT

PU

T

ODUCT OUTPUT

2

1

1

2

3

3

3

W

ATER

TER

IN

PU

T

INPUT

RE

FIL

L

REFILL

MA

IN

MAIN

PO

PO

W

ER

WER

If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the
wiring diagrams and check the dispenser wiring har-
ness.

5. Check for continuity across the switch terminals

with the switch in the “ON” position. Continuity
must not be present when the switch is in the
“OFF” position.

If continuity is present as described, reconnect the
wires to the switch terminals.
If continuity is not present as described, replace the
switch.