17

COMBINATION RATINGS -- CONTINUED

Unit Size ---

Series

Indoor Model

Cooling

Capacity

ARI Standard Ratings

Cooling

Heating

Furnace Model

Factory

Enhance

Standard

Rating

SEER

TDR

EER

High Temp

Low Temp

HSPF

E

Capacity E COP

H

Capacity H COP

048---A

CNRH*6024A**

45,500

TDR&TXV

13.20

11.00

47,500

3.22

29,800

2.48

8.0

355AAV060080

CNRH*6024A**

45,500

TDR&TXV

13.20

11.00

47,500

3.24

29,600

2.48

8.1

355AAV060100

CNRH*6024A**

45,500

TDR&TXV

13.20

11.00

47,500

3.22

29,600

2.48

8.1

355AAV060120

CNRH*6024A**

45,500

TDR&TXV

13.20

11.00

47,500

3.24

29,600

2.50

8.1

315(A,J)AV048090

CNRH*6024A**

46,000

TDR&TXV

13.50

11.20

47,500

3.26

29,600

2.50

8.1

315(A,J)AV060110

CNRH*6024A**

46,000

TDR&TXV

13.50

11.20

47,500

3.28

29,400

2.52

8.2

315(A,J)AV066135

CNRH*6024A**

46,000

TDR&TXV

13.50

11.20

47,500

3.30

29,400

2.54

8.2

315(A,J)AV066155

CSRH*4812A**

44,500

TDR&TXV

13.00

10.80

47,500

3.20

31,200

2.94

8.5

355AAV060080

CSRH*4812A**

44,500

TDR&TXV

13.00

10.80

47,500

3.22

31,200

2.96

8.6

355AAV060100

CSRH*4812A**

44,500

TDR&TXV

13.00

10.80

47,500

3.22

31,000

2.96

8.6

355AAV060120

CSRH*4812A**

45,000

TDR&TXV

13.00

10.80

47,500

3.22

31,000

2.96

8.6

315(A,J)AV048090

CSRH*4812A**

44,500

TDR&TXV

13.20

11.00

47,500

3.24

31,000

2.98

8.6

315(A,J)AV060110

CSRH*4812A**

44,500

TDR&TXV

13.20

11.00

47,500

3.26

31,000

3.00

8.7

315(A,J)AV066135

CSRH*4812A**

45,000

TDR&TXV

13.50

11.20

47,500

3.30

30,800

3.02

8.7

315(A,J)AV066155

CSRH*6012A**

45,500

TDR&TXV

13.20

11.00

48,000

3.26

29,800

2.48

8.1

355AAV060080

CSRH*6012A**

46,000

TDR&TXV

13.20

11.00

48,000

3.28

29,600

2.50

8.2

355AAV060100

CSRH*6012A**

46,000

TDR&TXV

13.50

11.20

47,500

3.26

29,600

2.50

8.1

355AAV060120

CSRH*6012A**

46,000

TDR&TXV

13.50

11.20

47,500

3.28

29,600

2.50

8.2

315(A,J)AV048090

CSRH*6012A**

46,000

TDR&TXV

13.50

11.20

47,500

3.30

29,600

2.52

8.2

315(A,J)AV060110

CSRH*6012A**

46,000

TDR&TXV

13.50

11.20

47,500

3.32

29,400

2.54

8.3

315(A,J)AV066135

CSRH*6012A**

46,000

TDR&TXV

13.50

11.20

47,500

3.34

29,400

2.54

8.3

315(A,J)AV066155

060---A

*FC4DN(F,B)060

59,500

TDR&TXV

13.00

10.80

58,500

3.46

37,200

2.50

7.9

FK4DNB006

58,500

TDR&TXV

13.20

11.00

59,500

3.34

38,000

2.40

7.7

CAR**6024A**

57,500

TDR&TXV

13.00

10.80

58,500

3.38

36,600

2.46

7.7

315(A,J)AV066135

CAR**6024A**

58,000

TDR&TXV

13.00

10.80

58,500

3.40

36,400

2.48

7.8

315(A,J)AV066155

CNRV*6024A**

57,500

TDR&TXV

13.00

10.80

59,000

3.36

36,400

2.46

7.7

315(A,J)AV066155

CNRH*6024A**

57,500

TDR&TXV

13.00

10.80

59,000

3.36

36,400

2.46

7.7

315(A,J)AV066155

CSRH*6012A**

57,500

TDR&TXV

13.00

10.80

59,000

3.42

36,400

2.48

7.8

315(A,J)AV066135

CSRH*6012A**

58,000

TDR&TXV

13.00

10.80

59,000

3.46

36,400

2.48

7.8

315(A,J)AV066155

* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:

Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit.

High---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 47_F (8_C) db 43˚F (6_C) wb air entering outdoor unit.

Low---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 17_F (±9_C) db 15˚F (±10_C) wb air entering outdoor unit.

SEER — Seasonal Energy Efficiency Ratio
COP — Coefficient of Performance
TDR — Time---Delay Relay
HSPF — Heating Seasonal Performance Factor
EER — Energy Efficiency Ratio