beautypg.com

Caution, Upflow furnace air filter table – Bryant CONDENSING GAS FURNACE 352MAV User Manual

Page 7

background image

7

BLOWER COMPARTMENT
a. Remove main furnace door.

(See Fig. 23)

b. Remove blower access panel.

(See Fig. 24)

NOTE:

It will be necessary to

remove 2 screws

• AIR FILTER LOCATED IN FIL-

TER CABINET
a. Remove filter cabinet door (See

Fig. 36 and 37)

NOTE:

It will be necessary to

remove 1 thumbscrew

3. Remove air filter from furnace.

• AIR FILTER LOCATED IN

BLOWER COMPARTMENT
BOTTOM:
a. Slide filter retainer sideways

until it is free of latch. (See
Fig. 25)

b. Slide air filter out of furnace.

(See Fig. 26)

• AIR FILTER(S) LOCATED IN

BLOWER COMPARTMENT
SIDE:
a. Remove filter retainer from

latch. (See Fig. 27.)

b. Gently remove air filter and

carefully turn the dirty side up
(if dirty) to avoid spilling dirt
from the filter. (see Fig. 28)

• AIR FILTER LOCATED IN FIL-

TER CABINET:
a. Slide air filter out of furnace.

Keep dirty side up (if dirty) to
avoid spilling dirt. (See Fig. 38
and 39)

23

24

4. Inspect the filter. If torn, replace it.

NOTE:

If washable filter that was

shipped with the furnace has been
replaced by:

a. Factory specified disposable

media filter – Do not clean. If
dirty, replace only with media fil-
ter having the same part number
and size. Install with airflow
direction arrow pointing towards
blower.

b. Electronic air cleaner (EAC) –

Refer to EAC owner’s Manual
for maintenance information.

25

26

27

28

5. Wash filter (if dirty) in sink, bath-

tub, or outside with a garden hose.
Always use cold tap water. A mild
liquid detergent may be used if

necessary. Spray water through fil-
ter in the opposite direction of air-
flow. Allow filter to dry.

6. Reinstall clean air filter

7. Reinstall filter retainer (for blower

compartment locations only)

8. Replace blower access panel and

main furnace door (See Fig. 29
and 30) or filter cabinet door (Fig.
40 and 41)

9. Turn on electrical supply to fur-

nace.

If your furnace air filter needs to be
replaced, be sure to use the same size
and type of filter that was originally
supplied. Use the furnace filter table
and compare your furnace size with
the proper filter size.

UPFLOW FURNACE AIR

FILTER TABLE

* Factory-provided with the furnace. Filters may be

field modified by cutting filter material and support
rods (3) in filters. Alternate sizes and additional fil-
ters may be ordered from your dealer.

AIR FILTER LOCATED IN BLOWER COMPARTMENT

FURNACE

CASING

WIDTH

(IN.)

FILTER SIZE

(IN.)

FILTER

TYPE

Side

Return

Bottom

Return

17-1/2

(1) 16 x

25 x 1*

(1) 16 x

25 x 1*

Cleanable

21

(1) 16 x

25 x 1

(1) 20 x

25 x 1*

Cleanable

24-1/2

(1 or 2) 16

x 25 x 1

(1) 24 x

25 x 1*

Cleanable

AIR FILTER LOCATED IN FILTER CABINET:

FILTER

CABINET

HEIGHT

(IN)

FILTER SIZE

(IN.)

FILTER

TYPE

16

(1) 16 x 25 x 1*

or (1) 16 x 25 x 4-5/16

Cleanable

Disposable

20

(1) 20 x 25 x 1*

or (1) 20 x 25 x 4-5/16

Cleanable

Disposable

24

(1) 24 x 25 x 1*

or (1) 24 x 25 x 4-5/16

Cleanable

Disposable

CAUTION

Use care when cutting support
rods in filters to protect
against flying pieces and
sharp rod ends. Wear safety
glasses, gloves, and appropri-
ate protective clothing. Failure
to follow this caution could re-
sult in personal injury.

!