Operation method, Set the buzzer mode – Yamato Scientific IN603W Low Temperature Incubators User Manual
Page 45

41
Operation Method
Set the Buzzer Mode
1
Select the item in function menu
• Check that the power in turned on.
FUNCTION
TROUBLE
ENTER
CANCEL
Buzzer mode
OFF
①
Press the FUNCTION key. The function menu
starts and the Sub Display displays the items.
Select the item using the FUNCTION key.
②
Display the "Buzzer mode" and press the ENTER
key.
Press the CANCEL key to cancel the function menu.
2
Select mode
Buzzer mode
OFF
↓
Buzzer mode
ON
①
The "" (cursor) goes out and the mode currently
selected blinks instead. Display the "ON" or
"OFF" using the "▼▲".
3
Set buzzer mode
TROUBLE
ENTER
CANCEL
Buzzer mode
ON
①
Press the ENTER key. The buzzer mode is
decided and the function menu selection screen
is displayed.
The buzzer at auto stop and at the end of program
operation does not sound when the buzzer mode is
turned to "OFF". It sounds when the safety device
works because a trouble occurs on the unit.
- BB300 Low Constant Temperature Water Bath (64 pages)
- BBL100 Low Constant Temperature Water Bath (61 pages)
- BH200 Thermo-Elite (37 pages)
- BH400 Thermo-Elite (42 pages)
- BM100 Water Baths (16 pages)
- BM110 Water Baths (16 pages)
- BM400 Water Baths/Oil Baths (22 pages)
- BM410 Water Baths (21 pages)
- BU200 Low Constant Temperature Water Bath (18 pages)
- CLH301 Cool Line (65 pages)
- CLS301 Cool Line (55 pages)
- DC400 Freeze Dryers (33 pages)
- DG400 Drying Ovens for Laboratory Tools (41 pages)
- DKN 302 Constant Temperature Drying Oven (50 pages)
- DN410H Constant Temperature Ovens (88 pages)
- DN410I Inert Oven (88 pages)
- DNF 400 Constant Temperature Ovens (76 pages)
- DVS402 Constant Temperature Drying Oven (47 pages)
- DX302 Constant Temperature Drying Oven (9 pages)
- DX302 Constant Temperature Drying Oven (40 pages)
- HC200 Cool Block (58 pages)
- HF100 Heating Block (29 pages)
- IJ100 Low Temperature Incubator (27 pages)
- IJ201 Low Temperature Incubator (50 pages)
- K400 Shaking incubator (36 pages)
- IN603 Low Temperature Incubators (68 pages)
- IQ820 Low Temperature Incubators (46 pages)
- IQ821 Low Temperature Incubators (47 pages)
- LT400A Laboratory Stirrer (21 pages)
- RE200 Evaporators, Rotary (29 pages)
- RE400 Evaporators, Rotary (21 pages)
- RE210 Evaporators, Rotary (28 pages)
- RE440 Evaporators, Rotary (25 pages)
- RE550 Evaporators, Rotary (22 pages)
- RT200 Solvent recovery unit (15 pages)
- SN 200 Autoclave, Sterilizers (66 pages)
- Vacuum controller Vacuum controller (34 pages)
- WG201 Water Purifiers (40 pages)
- WG221 Water Purifiers (51 pages)
- WR600A AutoPure (28 pages)
- WS200 Water Purifiers (32 pages)
- External output controller type Ⅳ CR (3 pages)
- Hitech controller type Ⅳ (34 pages)