beautypg.com

Attery, Echarge – Wood’s Powr-Grip MRTA611LDC2 User Manual

Page 35

background image

Rev 0.0/4-14

33

MRTA6-DC2: #35072

B

ATTERY

R

ECHARGE

Charge the battery whenever the battery gauge indicates diminished energy (see B

ATTERY

T

EST

preceding).

Caution: Make sure the lifter's power switch is in the OFF

( )

position.

Identify the input voltage marked on the battery charger, and plug it in to an appropriate power

source.

28

Use a ground fault circuit interrupter to reduce the risk of electrical shocks.

Make sure power source is equipped with ground fault circuit interrupter.

The power lamp (Ф) turns on, to indicate
that the charger is functioning. To
determine charging status, consult the six-

stage display on the charger. The battery
is ready for use at stage 3 and fully
charged at stage 5.
Normally, the battery should take no more

than 8 hours to charge completely.

29

If

not, check for the following conditions and
correct any deficiencies as directed:
• Power lamp (Ф) flashes: Charger is not connected to battery; reconnect charger (see

ASSEMBLY).

• Error lamp (!) turns on: Battery leads connected to the wrong poles; reverse battery leads.
• Error lamp (!) turns on and charging stops at stage 1 or stage 4: Battery is no longer

functioning; replace battery (see REPLACEMENT PARTS LIST).

Be sure to unplug the charger and test the battery energy again before operating the lifter (see

B

ATTERY

T

EST

preceding).

28

Any external power supply must conform to all applicable local codes.

Caution: Do not operate the lifter while the

charger is connected to an AC power source, since this could result in permanent damage to the charger.

29

The charger is designed to automatically sense the energy level of the battery and reduce the charging rate when the battery

is fully charged. Accordingly, the charger does not need to be unplugged until the lifter is going to be used again.