Change basic settings – Waldmann PULSE HFMD version VFC III - with MFT User Manual
Page 8

8
GB
Operating Manual Light control “PULSE HFMD - Vers. III“
GB
Operating Manual Light control “PULSE HFMD - Vers. III“
Change basic settings
Change to
parameterization mode
- Keep both keys [I and II] pressed
simultaneously for 2 seconds.
- The operating panel changes to
the parameterization mode (fi rst
to level 1).
- The background lit logo fl ashes
(once per second).
- In order to jump to a higher level,
both keys [I and II] have to be
held pressed until the logo stops
fl ashing (level 2) or until the logo
starts fl ashing again (level 3).
Change setting
The individual functions are selec-
ted via key II.
The light bar shows the selected
function.
The LED on the light bar indicates
whether a function is active (ON)
or inactive (OFF) by permanent
lighting or fl ashing, e.g.:
- LED constant dark green:
Function 1 active (On)
- LED fl ashing dark green:
Function 1 inactive (OFF)
The function can be activated or
deactivated by pressing the key I.
The parameterization mode is
left if no key has been pressed
for 10 seconds. The settings are
stored.
Fig. 4
Fig. 3
Key I
Logo
Light
bar
Key II
LED I
LED II
LED II
Key II
LED I
Key I
Sensor
- The LEDs [I and II] on the sen-
sor operating panel (see Fig. 4)
fl ash - according to the level) in
the respective color (once per
second):
LED II fl ashing white:
Level 1
- LED I and II fl ashing green:
Level 2
- LED I and II fl ashing blue:
Level 3