beautypg.com

Test points & sockets – Vicor VI Chip VTM Evaluation Board User Manual

Page 5

background image

UG:014

vicorpower.com

Applications Engineering: 800 927.9474

Page 5

Test Points and Sockets Description

Each test point socket accepts 0.015 – 0.025 inch diameter leads of solid wires and
through-hole components for use with external circuitry and test equipment. All test
points are aligned on the board’s edge for easy access, measurement and external
circuitry connections. Each point is labeled and is accompanied by an additional
adjacent socket.

Reference

Designator

Functional

Name

Functional
Description

TP20,

TP21

+IN,

–IN

Input voltage test points provide kelvin connection to input pins of the
VTM

®

. Use these test points for measuring the input voltage of the VTM

to avoid error due to interconnect losses.

H20,

H21

+IN,

–IN

Sockets for +IN and –IN test points. Kelvin connected to the VTM input
pins.

TP17,

TP22

+OUT,

–OUT

Output voltage test points provide kelvin connection to output pins of the
VTM. Use these test points for measuring the output voltage of the VTM
to avoid error due to interconnect losses.

H17,

H22

+OUT,

–OUT

Sockets for +OUT and –OUT test points. Kelvin connected to the VTM
output pins.

TP12

VC

VC test point provides kelvin connection to VC pin of the VTM. Can be
used to apply and measure the VC signal with reference to –IN signal. VC
is used to enable the VTM. Apply 14 V to VC to enable the VTM, when
not using PRM.

H12

VC

Socket for VC test point. Kelvin connected to VC pin of the VTM. Aligned
with –IN socket for placing through hole resistor from VC to –IN.

TP10

PC

PC test point provides kelvin connection to PC pin of the VTM. Can be
used to measure the PC signal with reference to –IN signal. PC can be
used to disable the VTM in the presence of input power. Connecting PC
to –IN will disable the VTM.

H10

PC

Socket for PC test point. Kelvin connected to PC pin of the VTM.

TP11

TM

TM test point provides kelvin connection to TM pin of the VTM. Can be
used to measure and monitor the TM signal with reference to –IN signal.

H11

TM

Socket for TM test point. Kelvin connected to TM signal of the VTM

TP16

FILTERED

TM

Provides the low noise measurement of TM signal.Output of the TM RC
filter can be measured using this testpoint with reference to –IN.

H15

FILTERED

TM

Socket for TP16 test point.

TP13

–IN

-IN test point provides kelvin connection to –IN pin of the VTM. All signals
on input side of the VTM are measured with reference to –IN signal of the VTM.

H13

–IN

Socket for –IN test point.

TP15,

TP14

+S,

–S

Output sense test points provide connection to the output pins of
VTM through local sense resistors. Routed to connector J11 for use
in differential non isolated remote sense circuitry for Remote Sense
operation of VTM and PRM

®

.

Table 1.

Test points and

sockets description