Vicor VI Chip VTM Evaluation Board User Manual
Page 2
UG:014
vicorpower.com
Applications Engineering: 800 927.9474
Page 2
Contents
All VTM® evaluation boards arrive with the following contents.
(The user guide can be downloaded from the
.)
n
1 x VTM Evaluation board
n
1 x VI Chip push pin heat sink
n
2 x VI Chip push pins for heat sink installation
n
1 x Hardware kit
n
2 x Through hole mating connectors
n
1 x Through hole 22 µF input capacitor
Features
1.
Input filtering – ceramic capacitors and sockets for installation of throughhole
aluminum electrolytic capacitor
2.
Output filtering – ceramic capacitors
3.
Oscilloscope probe jack for output voltage signal measurement
4.
Kelvin test points for measurement of input voltage, output voltage and all signal
pins of the VTM
5.
Sockets for each test points for easy installation of through-hole components and
solid wires to facilitate wiring to external circuitry and test equipment
6.
Input and output lugs for power supply and load connections
7.
Input power and signal connectors for testing with PRM module
8.
Provisions for non-isolated remote sense operation with PRM evaluation board
a. Provision to inject network analyzer signals
b. 2512 resistor footprint for installation of zero ohm resistor to break the VTM
isolation for non isolated remote sense operation
c. Sense pins with local Sense Resistors to +OUT and –OUT