Board operating modes, Line and load connections – Vicor VI Chip PRM Evaluation Board User Manual
Page 18
UG:013
vicorpower.com
Applications Engineering: 800 927.9474
Page 18
Line and Load connections
n
Make sure that input power supply is OFF.
n
Connect the input power supply positive lead to the +IN input lug of the
evaluation board.
n
Connect the input power supply return lead to the –IN input lug of the
evaluation board.
n
Connect the output lug +OUT to the positive terminal of the electronic load.
n
Connect the output lug –OUT to the return terminal of the electronic load.
n
Verify proper polarity of the connections.
n
Place the input capacitance 22 uF, 100 V.
n
Turn the FAN ON.
n
Have the latest version of the datasheet.
Board Operating Modes
PRM evaluation board supports both Adaptive Loop and Remotes Sense Operation.
Therefore, operating mode selection switch S10 is provided on the board for selection of
the following operating modes:
n
Default / Adaptive loop using PRM
n
Adaptive loop using PRM and VTM
n
Remote Sense: local sensing (single ended)
n
Remote Sense: non-isolated remote sense (differential)
n
Slave (for array operation)
ON
SGND
SHARE/CONTROL NODE
TRIM
EAO
IF B
IMON
LOCAL SENSE_ +
PRM_ +OUT
+SENSE_B
-SENSE_B
+SENSE
-SENSE
REF/REF_ EN
VAUX
VCC
REF_ EN_ B
V T
V T M_T M
i +S
i -S
i POU T
1 2 3 4 5 6 7 8 9
18 17 16 15 14 13 12 11
10
19
20
S10
SW_ 21910MST
i POU T
Figure 8.
Mode select switch