Evaluation Board Basic Specifications and Operating Limits

Please use the following table for operating limits:

Note: VI Brick AC Front End Module operating temperature will depend on its Product Grade as

specified in the datasheet.

Please refer to Figure 1 for locations of the input and output connections as viewed
from the component side. Wires may be soldered directly to the pads instead of ring
lugs if desired to minimize circuit impedances.

Figure 1

VI Brick

® AC Front End

Evaluation Board layout and

dimensional drawing,

component side.

Table 1

Operating Limits

Description

Specification Notes

Input Range

85 – 264 Vac

Universal input

Output voltage

48 Vdc

Partially Regulated, SELV

Output Power

330 W

Over entire input range

Operating temperature

-40 to 85°C

Limited by hold-up capacitor

and Z01

Output capacitance

6,000 to 12,000μF

63V rating