beautypg.com

Vicor PF175 AC-DC Converter Evaluation Board with External Input Filter User Manual

Page 6

background image

UG:100

vicorpower.com

Applications Engineering: 800 927.9474

Page 6

Figure 3.

Active transient suppression

section schematic

Figure 4.

Output enable control

schematic

Output Enable Control
The EN pin is pulled low to disable the AC-DC converter. If pulled high to 3.3 V or
left floating, the VI Brick® PFM® will operate. A 1x5 0.100” spaced socket allows easy
connection to automated test equipment. This part of the circuit is referenced to
primary ground.
Users can connect their own secondary referenced control circuit by connecting
through the optocoupler U01, and connecting to TP12 and TP11 as needed. JP04 can be
removed to allow a floating reference for the enable input. On this TP12 input, a high
signal will result in shutdown of the AC-DC converter.