Functional and Mechanical Layout

NU-, QU-, and RU-Series

MU-, PU-Series

LU-Series

Inputs

7
8
9

2.156 ±0.010

(54,76 ±0,25)

0.192 ±0.010

(4,88 ±0,25) 0.18

(4,57)

6.00

(152,4)

2.540 ±0.030

(64,52 ±0,76)

1.27

(32,26)

7
8
9

4.562 ±0.010

(115,87 ±0,25)

2.281 ±0.010

(57,94 ±0,25)

0.199 ±0.010

(5,05 ±0,25) 0.18

(4,57)

6.00

(152,4)

4.960 ±0.030

(125,98 ±0,76)

3.83

(97,16)

1.17

(29,72)

7
8
9

1
2
3
4
5
6

7.000 ±0.010

(177,8 ±0,25)

4.710 ±0.010

(119,63 ±0,25)

2.290 ±0.010

(58,17 ±0,25)

0.190 ±0.010

(4,83 ±0,25)

0.18

(4,57)

6.00

(152,4)

7.380 ±0.030

(187,45 ±0,76)

5.48

(139,19)

1.93

(49,02)

4

LU-Series

Single output
50-200 W

MU-Series

Single output
200-400 W

NU-Series

Single output
300-600 W

PU-Series

Dual output
100-400 W

QU-Series

Dual output
150-600 W

RU-Series

Triple output
150-600 W

Inputs

1 MOD DIS–
2 MOD DIS+
3 AC OK–
4 AC OK+
5 BUS OK–
6 BUS OK+
7 AC in L1
8 AC in L2/N
9 Chassis Ground

Outputs

10 +Power Out
11 +Out**
12 +Sense*
13 Trim*
14 –Sense*
15 –Out**
16 –Power Out

*On FlatPACs

containing BatMods:
12 V

TRIM

13 I

TRIM

14 I

MON

**For local sense

connection only —
not for load
connection

FlatPAC units are shipped with pins 11-12
and 14-15 connected via jumper plugs
(Vicor P/N 02589) for
local sense. For
remote sense, remove these connections
and connect pins 10-12 and 14-16, as
shown in the Output Sense and Trim
drawing on page 3.

All FlatPAC models are available
with a
conduction cooled flat plate
instead of the top heat sink. Contact
factory for outline drawings.