Functional and mechanical layout, Inputs, Outputs – Vicor FlatPAC Family 50 to 600 Watt AC-DC Switchers U-Series User Manual
Page 4: Nu-, qu-, and ru-series mu-, pu-series lu-series, 13 i, 14 i
Functional and Mechanical Layout
NU-, QU-, and RU-Series
MU-, PU-Series
LU-Series
Inputs
7
8
9
2.156 ±0.010
(54,76 ±0,25)
0.192 ±0.010
(4,88 ±0,25) 0.18
(4,57)
6.00
(152,4)
2.540 ±0.030
(64,52 ±0,76)
1.27
(32,26)
7
8
9
4.562 ±0.010
(115,87 ±0,25)
2.281 ±0.010
(57,94 ±0,25)
0.199 ±0.010
(5,05 ±0,25) 0.18
(4,57)
6.00
(152,4)
4.960 ±0.030
(125,98 ±0,76)
3.83
(97,16)
1.17
(29,72)
7
8
9
1
2
3
4
5
6
7.000 ±0.010
(177,8 ±0,25)
4.710 ±0.010
(119,63 ±0,25)
2.290 ±0.010
(58,17 ±0,25)
0.190 ±0.010
(4,83 ±0,25)
0.18
(4,57)
6.00
(152,4)
7.380 ±0.030
(187,45 ±0,76)
5.48
(139,19)
1.93
(49,02)
4
LU-Series
Single output
50-200 W
MU-Series
Single output
200-400 W
NU-Series
Single output
300-600 W
PU-Series
Dual output
100-400 W
QU-Series
Dual output
150-600 W
RU-Series
Triple output
150-600 W
Inputs
1 MOD DIS–
2 MOD DIS+
3 AC OK–
4 AC OK+
5 BUS OK–
6 BUS OK+
7 AC in L1
8 AC in L2/N
9 Chassis Ground
Outputs
10 +Power Out
11 +Out**
12 +Sense*
13 Trim*
14 –Sense*
15 –Out**
16 –Power Out
*On FlatPACs
containing BatMods:
12 V
TRIM
13 I
TRIM
14 I
MON
**For local sense
connection only —
not for load
connection
FlatPAC units are shipped with pins 11-12
and 14-15 connected via jumper plugs
(Vicor P/N 02589) for local sense. For
remote sense, remove these connections
and connect pins 10-12 and 14-16, as
shown in the Output Sense and Trim
drawing on page 3.
All FlatPAC models are available
with a conduction cooled flat plate
instead of the top heat sink. Contact
factory for outline drawings.