beautypg.com

Typical applications (models with batmods only) – Vicor FlatPAC Family 50 to 600 Watt AC-DC Switchers U-Series User Manual

Page 3

background image

3

+Sense and –Sense must be connected locally or remotely (shown).

RESISTOR VALUES FOR TRIMMING STANDARD OUTPUT VOLTAGES

Nominal

5 V

12 V

15 V

24 V

28 V

48 V

Trim Range

Output Voltage

R1(KΩ)

.953

15.8

22.1

41.2

48.7

90.9

+10%, -10%

R2(KΩ)

90

90

90

90

90

90

+10%, -10%

V

LINE

> 90 (180)Vac

AC Line

Interrupted

AC

Line

AC OK

BUS OK

T0 T1

T2

T3

T4

Conditions: Full Load 90 (180)Vac, AC Line

Timing Diagram—Status Signals

(2-up and 3-up models only)

Output Sense and Trim

(All models with VI-200s)

Load

+

Battery

Charger

External
Control
Functions

Programmable Current

or Voltage Source

12–48V

Battery

+

+Out

V

TRIM

I

TRIM

I

MON

–Out

External
Control
Functions

+Out

V

TRIM

I

TRIM

I

MON

–Out

Typical Applications

(Models with BatMods only)

Time Interval

Min

Typ

Max

Units

Notes

T1-T0

0

0.1

1.0

ms

T3-T2

0

ms

Ride-through time

T4-T2

5

ms

Hold-up time

T4-T3

5

ms

AC fail warning time

+Out

+Sense

Trim

–Sense

–Out

+ V

OUT

V

OUT

RTN

R2

R1

10K