Timing diagram—status signals, Output trimming, Typical applications – Vicor FlatPAC Family 50 to 600 Watt AC-DC Switchers A-Series User Manual

Page 3

background image

3

+Sense and –Sense must be connected locally or remotely (shown).

+ V

OUT

To Load

– V

OUT

R1

10K

R2

+ OUT

+ SENSE

TRIM

– SENSE

– OUT

RESISTOR VALUES FOR TRIMMING STANDARD OUTPUT VOLTAGES

Nominal Output Voltage 5 V 12 V 15 V 24 V 28 V 48 V

Trim Range

R1(k

)

.953 15.8 22.1 41.2 48.7 90.9

R2(k

)

90

90

90

90

90

90

+10%, -10%

V

LINE

> 90 (180) Vac

AC Line

Interrupted

AC

Line

AC OK

DC OK

T0 T1

T2

T3

T4

Conditions: Full Load 90 (180) Vac, AC Line

Timing Diagram—Status Signals

(2-up and 3-up models)

Output Trimming

(All models with VI-200s)

Battery

Charger

External
Control
Functions

+ OUT

V

TRIM

I

TRIM

I

MON

– OUT

Programmable

Current Source

12–48V

Battery

+

Load

+

OR

Typical Applications

(FlatPACs with BatMods only)

Time Interval

Min

Typ

Max

Units

Notes

T1-T0

0

0.1

1.0

ms

T3-T2

0

ms

T4-T2

5

ms

Ride-through time

T4-T3

5

ms

AC fail warning time