beautypg.com

Maintenance, Removing valve, Installing valve – Regency Panorama P33CE Small Gas Fireplace User Manual

Page 52

background image

52

Regency® P33CE Zero Clearance Direct Vent Gas Fireplace

MAINTENANCE

REMOVING VALVE

1. Shut off the gas supply.

2. Open

the

fl ush door (see instructions in this manual) and remove

the door.

3. Remove the burner/grate assembly by removing the two screws

and then lift the burner assembly out.

Diagram 1: Remove the left and right screws and then lift out the

burner/grate assembly.

4. Remove the rear log stand by removing the 2 screws.

INSTALLING VALVE

1. Install new valve assembly.

2. Reverse steps 7-1.

Diagram 5: Lift out Valve Tray Assembly

EV1

EV2

Ground

8. Remove valve tray assembly.

7. Remove the 12 screws securing the valve tray assembly in place

(Diagram 4) and then lift the entire assembly out.

Diagram 4 Valve Tray Assembly

Diagram 2

Diagram 3

Rear Log Stand

screws

5. Disconnect the inlet gas line.

6. Disconnect the EV1, EV2, and ground wires from the valve - as shown

below.