P33CE Direct Vent Gas Fireplace

27

INSTALLATION

Horizontal Venting with Three (3) 90

o

Elbows

Vertical Venting with Two (2) 90

o

Elbows

Vertical Venting with Two (2) 90

o

Elbows

For additional vertical venting with
2 x 90

o

elbows, refer to "Rigid Pipe

Venting Arrangements" Section.

One 90

o

elbow = Two 45

o

elbows.

Option

V

H

V + V1

H + H1

With these options,
maximum total pipe
length is 30 feet with
minimum of 12 feet
total vertical and
maximum 9 feet total
horizontal.

P l e a s e n o t e
m i n i m u m 1 f o o t
between 90

o

elbows

is required.

A)

2' Min.

1' Max.

3' Min.

4' Max.

B)

3' Min.

2' Max.

4' Min.

5' Max.

C)

4' Min.

3' Max.

6' Min.

6' Max.

D)

5' Min.

4' Max.

8' Min.

7' Max.

E)

6' Min.

5' Max.

10' Min.

8' Max.

F)

7' Min.

6' Max.

12' Min.

9' Max.

One 90

o

elbow = Two 45

o

elbows.

Option

V

H

V + V1

With these options,
maximum total pipe
length is 30 feet with
minimum of 6 feet total
vertical and maximum 8
feet total horizontal.

Please note minimum
1 foot between 90

o

elbows is required.

A)

1' Min.

4' Max.

2' Min.

B)

2' Min.

5' Max.

3' Min.

C)

3' Min.

6' Max.

4' Min.

D)

4' Min.

7' Max.

5' Min.

E)

5' Min.

8' Max.

6' Min.

One 90

o

elbow = Two 45

o

elbows.

Option

H + H1

V

With these options, maximum
total pipe length is 30 feet
with minimum of 6 feet total
vertical and maximum 6 feet
total horizontal.

Please note minimum 1
foot between 90

o

elbows is

required.

A)

2' Max.

2' Min.

B)

3' Max.

3' Min.

C)

4' Max.

4' Min.

D)

5' Max.

5' Min.

E)

6' Max.

6' Min.