beautypg.com

Installation, P q o n, Framing dimensions – Regency Panorama P33CE Small Gas Fireplace User Manual

Page 13: Gh i j

background image

P33CE Direct Vent Gas Fireplace

13

INSTALLATION

FRAMING DIMENSIONS

* Measured from base of unit

M

L

K

P Q

O

N

Opening for gas

connection

J

I

Floor

DETAIL N

SCALE 1 : 6

2X4 HEADER

N

Non-combustible

Header

(steel stud

on edge)

G

H

I

J

NOTE: If this is an outside corner, the

minimum distance between the vent
and the outside corner is 6" (15cm)
with AstroCap termination cap or 12"
(30cm) with Rigid Vent termination cap.

(For example Dura-Vent)

Framing Dimensions

Description

P33CE

P33CE

With Non-Combustible Board Only

(i.e. Painted Finish)

With Tile, Stone, Brick, Slate,

Modera Mantel, Verona Surround

or other Non-Combustible fi nish

G

Framing Width

35"(889mm)

35"(889mm)

H

Framing Height *

31-3/4" (806mm)

31-3/4" (806mm)

I

Framing Rise from Floor

0"

(when not using a surround / mantel)

0"

2" min (w/ Modera Mantel)

3-5/16" min (w/ Verona Surround)

J

Framing Depth Vertical
Horizontal

23-1/4" (578mm) Vertical Rise

20-1/4" (502mm) Rigid / 16-1/2" (406mm) Flex

22-3/4" (578mm) Vertical Rise

19-3/4" (502mm) Rigid / 16" (406mm) Flex

K

Corner Wall Length

39-1/4" (988mm)

38-15/16" (988mm)

L

Corner Facing Wall Width

55-1/2" (1410mm)

54-1/2" (1410mm)

M

Framed Chase Ceiling*

36" (914mm) Rigid

32" (812mm) Flex

36" (914mm) Rigid

32" (812mm) Flex

N

Vent Centerline Height*

30" (762mm) Rigid

26" (660mm) Flex

30" (762mm) Rigid

26" (660mm) Flex

O

Gas Connection Height*

1 1/2" (38mm)

1 1/2" (38mm)

P

Gas Connection Inset*

7-3/16" (183mm)

7-3/16" (183mm)

Q

Gas Connection Width*

3" (76mm)

3" (76mm)