42

P33CE Direct Vent Gas Fireplace

INSTALLATION

Optional

WALL SWITCH

1) Run the supplied 10' of wire through the right

or left side gas inlet opening. Be careful not to
damage wire.

Note: We recommend a maximum of 10' of

wire but if you wish to go with a longer
run, use the Thermostat Wire Table.

2) Connect the wire to a wall switch and install

into the receptacle box. Also attach wires to
the valve as shown below.

Optional

WALL THERMOSTAT

A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram. Use
table below to determine the maximum wire length.

Note: Preferable if the thermostat is installed

on an interior wall.

Regency

®

offers an optional programmable

thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.

Thermostat Wire Table

Optional

REMOTE CONTROL

Use the Regency

®

Remote Control Kit approved

for this unit. Use of other systems may void your
warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting plate.

1) Choose a convenient location on the wall to

install the receiver and the receptacle box
(protection from extreme heat is very important).
Run wires from the fi replace to that location.

2) Connect the two wires to the gas valve. See

wiring diagram. Optional wall switch GT/GTM/
GTMF using wire 0.584.907

3) Install 3 AAA alkaline batteries in transmitter and

4 AA alkaline batteries in the receiver. Install
the receiver and its cover in the wall. Switch
the remote receiver to "remote" mode. The
remote control is now ready for operation.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

14 GA.

50 Ft.

16 GA.

32 Ft.

18 GA.

20 Ft.

20 GA.

12 Ft.

22 GA.

9 Ft.

BATTERY INSTALLATION

1) 4 AA batteries must be installed in the battery pack to operate the burner switch.

2) Install 2 AA batteries per side and connect as shown below.

CAUTION

Do not wire millivolt

wall thermostat wires

to 120V wire.

CAUTION

Do not wire millivolt

remote control wires

to 120V wire.

CAUTION

Do not wire millivolt

wall switch wires

to 120V wire.