Installation – Regency Panorama P33CE Small Gas Fireplace User Manual
Page 22
22
P33CE Direct Vent Gas Fireplace
INSTALLATION
Description
Simpson
Direct Vent Pro
®
Selkirk
Direct Temp™
American Metal
Products®
Amerivent Direct
Metal-Fab™
Sure Seal
Security
Secure- Vent®
ICC Excel
Direct
Attic Insulation Shield 12”
46DVA-IS
N/A@ FPI
N/A
4DAIS12
N/A
SV4RSA
N/A
Attic Insulation Shield -
Cold Climates
36”
N/A
N/A
4DAIS12
N/A
N/A
TM-4AS
High Wind Vertical Cap
46DVA-VCH
N/A
N/A
N/A
N/A
TM-4VT
High Wind Horizontal Cap
46DVA-HC
N/A
N/A
N/A
N/A
TM-4DHT
Horizontal Square Termination Cap
See
46DVA-HC
4DT-HHC
4DHC
4DHT
SV4CHC-1
TM-4HT
Vertical Termination Cap
46DVA-VC
4DT-HVC
4DVC
4DVT
SV4CGV-1
TM-4VT
Storm Collar
46DVA-08A
4DT-SC
4DSC
4DSC
SV4FC
TM-SC
Restrictor Disk
N/A
N/A
N/A
N/A
N/A
TM-4DS
Extended Vertical Termination Cap
N/A
N/A
N/A
N/A
N/A
N/A
Chimney Conversion Kit A (USA only)
46DVA-KCA
N/A
N/A
N/A
N/A
TM-4CA6
Chimney Conversion Kit B (USA only)
46DVA-KCB
N/A
N/A
N/A
N/A
TM-4CA7
Chimney Conversion Kit C (USA only)
46DVA-KCC
N/A
N/A
N/A
N/A
TM-4CA8
Chimney Conversion Kit Masonry
(USA only)
46DVA-KMC
N/A
N/A
N/A
N/A
N/A
Wall Firestop
46DVA-WFS
N/A
N/A
N/A
N/A
TM-4TR
Colinear Flex Connectors
46DVA-ADF
N/A
N/A
N/A
N/A
N/A
Adjustable Flashing 0/12-6/12
46DVA-F6
4DT-ST14
4D12S
4DST14
SV4STC14
TF-4FA
Adjustable Flashing 6/12-12/12
46DVA-FLA
4DT-ST36
4D36S
4DST36
SV4STC36
TF-4FB
Vinyl Siding Standoff
46DVA-VSS
4DT-VS
N/A
4DVS
SV4VS
TM-VSS
Vinyl Siding Shield Plate
N/A
4DT-VSP
N/A
N/A
SV4VS
N/A
Snorkel Termination 14”
46DVA-SNKL
N/A
N/A
N/A
N/A
TM-4ST14
Snorkel Termination 36”
N/A
N/A
N/A
N/A
N/A
TM-4ST36
Basic Horizontal Termination Kit (A)
Disc.
4DT-HKA
4DHTK2
4DHTKA
SV-SHK
N/A
Horizontal Termination Kit (B)
46DVA-KHA
(Changed Components)
4DT-HKB
4DHTK1
4DHTKB
SV-HK
N/A
Vertical Termination Kit
Disc.
4DT-VKC
4DHTK
4DHTK
SV-FK
N/A
FPI
946-506/P
Vent Guard (Optional) for AstroCap
946-205
Vinyl Siding Shield for Riser Vent Terminal
510-994
Rigid Pipe Adaptor (Must use with all rigid piping)
946-208/P
Vent Guard (Optional) for Riser Vent Terminal
640-530/P
Riser Vent Terminal
946-523/P
AstroCap Horizontal Cap
946-605
Starter Collar Increaser 4” x 6-5/8” to 5” x 8”
946-206
Vinyl Siding Standoff for AstroCap
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
4” x 6-5/8” Venting
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Run (X)
Rise (Y)
0” (0mm)
4-7/8” (124mm)
13-7/8” (340mm)
Simpson Direct Vent Pro: www.duravent.com
6” (152mm)
8” (203mm)
16-1/2” (419mm)
Selkirk Direct-Temp: www.selkirkcorp.com
9” (229mm)
10-1/8” (257mm)
18-5/8” (473mm)
American Metal Products: www.americanmetalproducts.com
12” (305mm)
12-1/4” (311mm)
20-3/4” (527mm)
Metal-Fab Sure Seal: www.mtlfab.com
24” (610mm)
20-5/8” (524mm)
29-1/8” (740mm)
Security Secure Vent: www.securitychimneys.com
36” (914mm)
29” (737mm)
37-1/2” (953mm)
Industrial Chimney Company: www.icc-rsf.com
48” (1219mm)
37-7/16” (951mm)
45-15/16” (1167mm)