Regency Horizon™ HZO42 Gas Fireplace

9

INSTALLATION

Caution Requirements

The top, back and sides of the fi replace are defi ned by

standoffs. The metal ends of the standoff may NOT be

recessed into combustible construction.

WARNING

Fire hazard is an extreme risk

if these clearances (air space) to combustible materials are not

adhered to. It is of greatest importance that this fi replace be

installed only in accordance with these instructions.

MINIMUM CLEARANCES TO COMBUSTIBLES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
fi replace be installed only in accordance with these instructions.

F

E

D

A

C

B

HZO42 Clearance Requirements

Clearance:

Dimension

Measured From:

A: Sidewall

11" (203mm)

Side of Fireplace Opening

B: Ceiling

36" (914mm)

Top of Fireplace Opening

C: Mantel Height (min.)

18" (457mm)

Top of Fireplace Opening

D: Mantel Depth (max.)

12" (304mm)

From Wall

E: Alcove Width

57"(1148mm)

Wall to Wall (Minimum)

F: Alcove Depth

36" (914mm)

Front to Back Wall (Maximum)

Notes:

0"

No Hearth Required

E

F

Alcove

A

B

WARNING:

When installing this appliance; do not cover or surround
with insulation.
This appliance can overheat and cause malfunction
and component failure, if covered, or partially covered.
If the appliance is installed inside a chase, insulation
must be installed on the walls of the chase, not on the
appliance.