beautypg.com

Maintenance, Digital fireplace burner control removal – Regency Horizon HZO42 Outdoor Gas Fireplace User Manual

Page 36

background image

36

Regency Horizon™ HZO42 Gas Fireplace

MAINTENANCE

DIGITAL FIREPLACE BURNER CONTROL REMOVAL

5. Disconnect the Black sparker wire with black spade connector from CN3.

See Diagram 2 below.

6. Disconnect the white and green On/Off switch wires.

See Diagram 3 below.

7. Disconnect the yellow ground wire with green diagonal stripe for pilot

(CN2). See Diagram 4 below.

8. Disconnect the three valve wires (yellow wire with green stripe).

See Diagram 5 below.

Diagram 1

Diagram 5

Diagram 2

Diagram 3

Green

White

Diagram 4

Pilot Sensor

Wire

Sparker Wire

ON/OFF wires

Ground wire

Valve wire

2. Remove the DFC from the fl oor of the fi rebox by removing 2 screws in

locations shown below to release DFC bracket.

4. Disconnect the Black Pilot sensor wire with Red Spade connector from

the 'ON' on DFBC (Digital fi replace burner control) box.

See Diagram 1 below.

1 Remove 6 screws in locations shown below to access DFC.

6th screw located at back