3. PRE-INSTALLATION SURVEY
The SER / IR heating system must have gas piping of correct diameter, length, and arrange-
ment to function properly. For this reason, a layout drawing is necessary. Carefully survey area
to be heated. For best results, whenever possible, place burner and combustion chamber in cold-
est area.
2. INSTALLATION IN GARAGES
SER / IR Series tube heaters are approved for use in garages. The installation must conform to
local building codes or, in the absence of local codes, to the standard NFPA No. 54 (ANSI
Z223.1 latest edition), in the U.S.A. and the CSA B149.1-00, and CAN1.2.16-M81 in Canada.
In a garage installation, the minimum clearance from the bottom of an infra-red heater to the
upper surface of a vehicle shall not be less than the certified clearance to combustible material
as indicated on the heater.
**"SU" Tube Kit includes a JS-0513-CU Turn Box, packed and
shipped in a separate carton.
Stand-Alone Tube Kits require no additional tube kits.
Primary Tube Kits require at least one additional Secondary Tube Kit.
Secondary Tube Kits require a Primary Tube Kit.
Secondary Tube Kit TM-1010-SX can also be used as a 10 ft extension kit. The installer
may
need to remove the turbulator (refer to Turbulator Chart in the I&O Manual).
4. MOUNTING CLEARANCES
SER / IR Series tube heaters must be mounted with minimum clearances between
the reflector surface and combustibles as shown in FIGURE 1, TABLE 2 (page 3).
For recommended heater placement refer to TABLE 3 (page 3). Heaters should also be lo-
cated in relation to building construction and equipment, to allowing a minimum clearance of
16 inches from end of burner housing to enable servicing and cleaning of burner, blower and
controls.
BURNER & TUBE KIT ASSEMBLY CHART
MODELS:
SER
& IR
:
Residential Garage/Workshop Heaters
TM-
TM-
TM-
TM-
TM-
4510-
4520-
1420-
1430-
1410-
SX
SX
SX
SX
SU**
10'
1
20'
1
20'
1
30'
1
10' U
1
TUBE KIT PART # & QUANTITY REQUIRED
60,000
Stand-Alone Kits Only
45,000
BURNER KIT
FIRING RATE