Schwank bistroSchwank 2-Stage User Manual
Page 23
2100 / IO 100 Manual
IM110107
RD: MAY 2014
R.L. 4A
23
Service Access - Electrical & Gas Components
Handle parts carefully to avoid scratching or damaging the surface finish:
1. Remove four sheet metal screws that hold the service access panel in place
2. Remove service from heater assembly
3. Component parts are accessible for service
4. Reassemble access panel to heater after service
Service Access - Burner & Ceramic Tiles
Handle parts carefully to avoid scratching or damaging the surface finish:
1. Remove six sheet metal screws that hold burner end plate in place
2. Remove end plate from heater assembly
3. Slide screen frame from heater assembly
4. Burner assembly is accessible for service
5. Reassemble after service
Servicing of heater is essential for continued efficient operation. Servicing should be carried
out annually by a qualified gas service technician as follows:
Clean the ceramic tiles with compressed air. Avoid directing air stream at gasket material
between tile and heater body. The air pressure must be lower than 20 psig.
Clean venturi tube with compressed air. The air pressure must be lower than 20 psig.
Ensure gas orifice is clean and the heater cabinet is free of any debris
13. SERVICING GUIDE (Also refer to Troubleshooting Guide on page 30)