Schwank bistroSchwank 2-Stage User Manual
Page 11

2100 / IO 100 Manual
IM110107
RD: MAY 2014
R.L. 4A
11
MODEL*
Voltage
VAC
Current
amps
Btu/hr input
Total Weight
lbs. [kg]
Length
Inches [mm]
2135
(-SS) / IO-135 (-SS) 24
40 VA**
35,000
39 [18]
44” [ 1118]
2150
(-SS) / IO 150 (-SS)
24
40 VA**
50,000
44 [20]
44” [ 1118]
2152
(-SS) / IO 152 (-SS)
24
40 VA** 50,000 / 36,500
44 [20]
44” [ 1118]
HEATER DIMENSIONS & CONFIGURATIONS
Figure 3: DIMENSIONS
Side View
Table 3: CAPACITIES & CONFIGURATIONS
Add fuel gas designation to model number: -N for natural gas; -L for
Standard model constructed of weather resistant aluminized steel with a high temperature
flat black coating. The “-SS” model is constructed with a stainless steel weather enclosure
Model 2152 / IO-152 is a two-stage heater
** Transformer Capacity: For multiple heater installation, the first heater requires 40VA and
each consecutive heater requires 20VA. The sum total will be the required Transformer capac-
ity. If total VA exceeds one transformer capacity select the next higher VA rated transformer.
End View
MOUNTING KIT OPTIONS see illustrations next page
ITEM NO
PART NUMBER
DESCRIPTION
1
JP-2100-MB
WALL MOUNTING BRACKET
2
JP-2300-MK
ARM MOUNTING BRACKET
3
JP-2300-PK
POST BRACKET
Chain mounting bracket JP-2100-HS is supplied as an integral part of the heater.
Other optional mounting kits are available:
WARNING: Wall Mounting Bracket JP-2100-MB, or Arm Mounting Bracket JP-2300-MK:
Ensure that anchoring to the structure is of sufficient strength, integrity and
workmanship, to adequately support the weight of the heater and any other
potential loads such as snow build up. Mount heater up to maximum 30° angle.
11”
44”
10.5”