S100-F / ITB-F I&O Manual
IM101230
RD: SEP 2014
RL: 11A
23A. BURNER & TUBE KIT ASSEMBLY CHART MODELS S100 / ITB
MODELS S100 & ITB are approved for indoor commercial / industrial non-residential applica-
tions. For outdoor, wet and harsh environment applications refer to models SPW-JZ / IWP
(powder coated burner box) and/or STW-JZ / IW (stainless steel burner box).
BEFORE INSTALLING: ENSURE you have the CORRECT TUBE KIT(s) for the
BURNER INPUT
Tube Kit Gross
Weight (lbs)
80
120
120
170
210
165
165
120
165
Tube Length (ft)
10'
20'
20'
30'
40'
30'
30'
20'
30'
INPUT (Btuh)
TM-4510-
SX
TM-1020-
SX
TM-1420-
SX
TM-1430-
SX
TM-1040-
SX
TM-F030-
SX
TM-1030-
SX
TM-0020-
SX
TM-0030-
SX
10'
1
20'
1
20'
1
30'
1
20'
1
30'
1
40'
1
100,000
20'
1
30'
1
40'
1
50'
1+ 1
30'
1
40'
1
50'
1+ 1
40'
1
50'
1+ 1
60'
1+ 1
50'
1+
1
60'
1+
1
70'
1+
2
50'
1+
1
60'
1+
1
70'
1+
2
*NOTE: S100 Series tubes are NOT emissive coated
(except 10' x 45,000 & 20' x 100,000 Btuh tubes are emissive coated)
Stand-Alone tube kits require no additional tube kits.
Primary tube kits require at least one additional Secondary tube kit.
Secondary tube kit require a Primary tube kit.
S100 / ITB - TUBE KIT PART # & QUANTITY REQUIRED
Stand-Alone Kits
Primary Kits
+ Secondary Kits
80,000
110,000
45,000
60,000
175,000
200,000
130,000
155,000
USA - Stainless Steel Flexible Gas Connector
130,000 or less:
JL-0771-XX - 1/2”x24”
155,000 or more:
JL-0771-YY - 3/4”x36”
FLEXIBLE GAS CONNECTOR (Included in Burner Kit) - MUST INSTALL - see Section 13
CANADA - Type 1 Hose Gas Connector
130,000 or less:
JL-0771-RC - 1/2”x30”
155,000 or more:
JL-0771-RB - 3/4”x30”