Schwank P40U Fenwal User Manual
Page 43
43
P40U-F / P40U-IF I&O Manual
IM101220
RD: MAY 2014
RL: 5A
JS-0502-UR-GK PROTECTIVE GUARD SCREEN OPTION – Zinc Plated; Two Piece Kit
– Recommended for heater mounted with less than 8 feet [2.4 m] between floor and bottom of
heater or patio heating applications
Two sections make up the protective guard assembly that installs on the underside of the P40-U heater.
Near the bottom edge at each side of the reflector are two sets of three holes. Each set of holes has
one round hole at the center of the reflector, the other two holes are elongated and positioned between
the center and the ends of the reflector. The pins that extend from each side of the two guard sections
are inserted into these sets of holes.
Fig. 1
Fig. 2
Step 1: On ONE SIDE of the reflector, remove the bottom screws (Qty 3) that fasten the reflector to the
end and center hanger brackets, Fig. 1. Retain screws for re-attachment of reflector .
Step 2: On the side of the reflector that remains securely fastened to the hangers, insert a pin located
at the end of the Protective Guard into one of the 1/8” round holes located at the center of the
reflector, Fig. 2
Fig. 3
Fig. 4
STEP 3: Continue installing pins into the reflector until all three pins on one side of the heater are