3.1 Internal Battery Power Supply

The EDL175 includes a rechargeable battery. When fully charged, the battery allows the
EDL175 to work for at least 20 minutes. Do not allow the battery to totally discharge. The
battery measurement sockets can be used for external 12V battery connection, which will
allow prolonged use of the EDL175 in the event of no network power supply.

Charging the Battery

When the battery is fully discharged (indicated by the buzzer, the blinking LOW BAT lamp
and, upon end of discharging, by no display), apply AC voltage to the EDL175 to recharge
the battery. The recommended charge time is 8 hours.

3.2 Indicators

The following table lists the possible indicated conditions:

2.8.

2

Special Cables

The manufacturer's special cables, together with the standard clamps, enable the EDL175

to perform measurements on high voltage lines via existing current transformers with 5A
nominal secondary current by measuring the output of the current transformers.

2.8.

3

Standard FLEX Current Sensors

The EDL175 can work with all standard FLEX and clamp current sensors which have a
voltage output up to 3V RMS. The EDL175 provides an optional FLEX connector cable for

connection to these current sensors.

Green LED –

AC and net-
work neon

light

Red LED –
BAT

Red LED –
LOW BAT

PM175
Display

Indication

ON

Off

Off

ON

EDL175 supplied by external AC power
supply; battery is charging slowly

Off

ON

Off

ON

EDL175 supplied by internal charged DC

battery

Off

ON

Blinking &

buzzer

ON

EDL175 supplied by internal DC power

supply; battery needs charging and will
disconnect automatically within 5 minutes

ON

Off

Off

Off

EDL175 is connected to external AC power
supply, slide switch is OFF; battery is

charging rapidly