ENGINE OPERATING PANEL

The defi nitions below describe the controls and functions
of the DCA400SSI Engine Operating Panel (Figure 5).

Tachometer

1.

— Indicates engine speed in RPM’s for 60

Hz operation. This meter should indicate 1800 RPM’s
when the rated load is applied. In addition a built in hour
meter will record the number of operational hours that
the generator has been in use.

Oil Pressure Gauge

2.

— During normal operation this

gauge be should read between 28 to 85 psi. (193~586
kPa). When starting the generator the oil pressure may
read a little higher, but after the engine warms up the oil
pressure should return to the correct pressure range.

Water Temperature Gauge

3.

— During normal operation

this gauge be should read between 167° and 203°F
(75°~95°C).

Charging Ammeter Gauge

4.

— Indicates the current

being supplied by the engine’s alternator which
provides current for generator’s control circuits and
battery charging system.

Fuel Gauge

5.

— Indicates amount of diesel fuel available.

Engine Warning Lamps

6.

— There are three engine

warning lamps, they are defi ned as follows:

Overheat Lamp

a.

— This lamp goes ON

when the cooling water temperature rises
abnormally. If the lamp goes ON during
normal operation of the generator, the
emergency shutdown device will stop the
engine automatically.

Low Oil Pressure Lamp

b. —

During

normal operation of the generator this
lamp should remain OFF. When the
Auto-OFF/Reset-Manual switch is set

to the MANUAL position to start the engine, the
lamp will be lit. When the oil pressure rises after
start-up the lamp will go OFF. If this lamp is ever
lit (ON) during normal operation of the generator,
the emergency shutdown device will stop the engine
automatically.

Low Fuel Level Lamp

c.

— When this lamp

is ON, it is time to stop the engine and
add fuel. Remember to let the engine cool
before adding fuel.

Air Filter Alarm

d.

— When the air fi lter

element is clogged, this lamp goes ON
indicating the element should be
immediately cleaned or replaced.

Coolant Level Alarm

e. —

This

lamp

goes ON when the coolant level is
low. If this lamp goes ON while the
engine is in operation, the emergency
shutdown device will automatically stop
the engine.

Engine Speed Switch

7.

— This switch controls the

speed of the engine (low/high).

Pre-Heat Lamp

8.

— When ECU is placed in AUX

position, pre-heat lamp will be ON. When pre-heat
cycle is completed, lamp will turn OFF.

Emergency Stop Button

9.

— Push this button inward to

stop the engine in the event of an emergency. DO NOT
use this button as a means of stopping the engine.

Battery Switch

10.

— This switch should be set to the ON

position during normal operation. When the engine has
been stop, place this switch in the OFF position. DO
NOT
turn this switch during normal operation, it could
cause damage to the electrical equipment.

Engine Operating Panel

Figure 5.

OFF

ON

OIL PRESS.

FUEL LEVEL

WATER TEMP.

1

2

3

4

5

6

7

9

10

AIR FILTER

COOLANT LEVEL

8