beautypg.com

Caution, Caution caution, Dca-180ssk — generator shutdown procedure – Multiquip DCA180SSK User Manual

Page 53

background image

DCA-180SSK — PARTS AND OPERATION MANUAL— REV. #3 (06/11/09) — PAGE 53

Figure 57. MPEC Engine Running

Status LED (OFF)

NEVER stop the engine suddenly except
in an emergency. DO NOT use the
emergency stop switch a as method of
shutting down the engine. This switch is
ONLY to be used in the event of an

emergency.

1. To stop the engine in the event of an emergency, PUSH

the emergency stop button ( Figure 58) inward. This button
is located on the generator's engine operating panel,
see page 32, Figure 10.

Emergency Stop

CAUTION

CAUTION

CAUTION

CAUTION

CAUTION:

Figure 58. Emergency Stop Button

Figure 56. Off/Manual Auto Switch (OFF)

Engine Shutdown
To shutdown the generator use the following procedure:

1. Place both the MAIN, GFCI and LOAD circuit breakers

to the "OFF position".

Figure 55. Engine Speed Switch

5. Verify that the "Engine Running" status LED (Figure 57)

on the Microprocessor Engine Control Module (MPEC)
display is "OFF" (not lit).

3. Let the engine cool by running it for 3-5 minutes with no

load applied.

6. Remove the load from the UVWO terminal strip (Figure 14

on page 35).

2. Set the engine speed switch (Figure 55) to the idle (low)

position.

4. Place the Off/Manual/Auto Switch (Figure 56) in the "OFF/

RESET" position

DCA-180SSK — GENERATOR SHUTDOWN PROCEDURE