OUTPUT TErMINAL PANEL CONNECTIONS

3Ø-480/277V UVWO Terminal Output Voltages

Place the voltage selector switch in the 3Ø 480/277

1.

position as shown in Figure 24.

Voltage Selector Switch

figure 24.

3Ø-480/277V Position

connect the load wires to the UVWO terminals as

2.

shown in Figure 25.

UVWO Terminal Lugs

figure 25.

3Ø-440/254V Connections

Turn the voltage regulator knob (Figure 20) clockwise

3.

to increase voltage output, turn counterclockwise

to decrease voltage output. Use voltage regulator

adjustment knob whenever fine tuning of the output

voltage is required.

1Ø-240/120V UVWO Terminal Output Voltages

Place the voltage selector switch in the 1Ø 240/120

1.

position as shown in Figure 26.

Voltage Selector Switch

figure 26.

1Ø-240/120V Position

connect the load wires to the UVWO terminals as

2.

shown in Figure 27.

UVWO Terminal Lugs

figure 27.

1Ø-200/100V Connections

Turn the voltage regulator knob (Figure 21) clockwise

3.

to increase voltage output, turn counterclockwise to

decrease voltage output. Use voltage regulator

adjustment knob whenever fine tuning of the output

voltage is required.

NOTICE

alWaYS make sure that the connections to the UVWO

terminals are

secure and tight. The possibility of arcing

exists, that could cause a fire.