gENErATOr OUTPUTS/gAUgE rEADINg

hoW to reaD the aC ammeter anD aC

voltage gaugeS

The Ac ammeter and Ac voltmeter gauges are controlled

by the Ac ammeter and Ac voltmeter change-over

switches.

Both of these switches are located on the control panel and

DO NOT effect the generator output. They are provided to

help observe how much power is being supplied, produced

at the UVWO terminals lugs.

Before taking a reading from either gauge, set the

Voltage

Selector Switch (Figure 13) to the position which produces

the required voltage (For example, for 3Ø 240V, choose

the center 3Ø 240/139V position on the voltage selector

switch)

Voltage Selector Switch

figure 14.

240/139V 3

Ø Positio

Ac Voltmeter Gauge Reading

Place the

AC Voltmeter Change-Over Switch (Figure 15)

in the W-U position and observe the phase to phase voltage

reading between the W and U terminals as indicated on

the

AC Voltmeter Gauge (Figure 16)

NOTICE

For 3Ø 208V/1Ø,120V, place the Voltage Selector

Switch in the 3 Phase 240/139 position.

aC voltmeter

Figure 15.

Change-over Switch

aC voltmeter

Figure 16.

Gauge

aC ammeter gauge reading

Place the

AC Ammeter Change-Over Switch (Figure 17)

in the U position and observe the current reading (load

drain) on the U terminal as indicated on the

AC Ammeter

Gauge (Figure 18). This process can be repeated for

terminals V and W.

AC Ammeter

figure 17.

Change-Over Switch

AC Ammeter

figure 18.

(Amp reading on U Lug)

NOTICE

The

ammeter gauge will only show a reading when

the

Output Terminal Lugs are connected to a load

and in use.