beautypg.com

Tlg-12spx — control panel – Multiquip TLG12SPX User Manual

Page 25

background image

TLG-12SPX — PARTS AND OPERATION MANUAL (STD) — REV. #4 (03/08/05) — PAGE 25

TLG-12SPX — CONTROL PANEL

The definitions below describe the controls and functions of
the TLG-12SPX "

Control Panel " (Figure 6).

1.

Circuit Breaker – This three-pole, 65 amp breaker is
provided to protect the UNV voltage output terminals
from overload.

2.

Frequency Meter – Indicates the output frequency in
hertz (Hz). Normally 60 Hz ±1 Hz .

3.

AC Voltmeter – Indicates the single phase output
voltage present at the UNV terminals.

4.

AC Ammeter – Indicates the amount of current the
load is drawing from the generator.

5.

Indicator Lamp - This engine waring indicator will notify
possible damage before it occurs:

A. Oil Pressure - the light will go on during initial

start, but will go out once the engine is warm. If the
oil pressure light comes on during operation, this may
indicate critical low oil level.

B. Charge Light - This light indicates the battery is

not charging.

C. Water Temperature Light - This light indicates the

coolant temperature is abnormally high.

D. Engine Protection - This will shut down the engine

if there is an abnormal event that may have occurred.
This prevents damage to the engine.

6.

Starter Switch - This is to turn on and off the engine
with a key.

7.

Hour Meter - This indicates the amount of time the
generator has been running.

8. Voltage Regulator Control – Allows manual adjustment