beautypg.com

Maintenance – Multiquip MVH406DSCP User Manual

Page 27

background image

mvh406dsz/dsCpas pLaTe COmpaCTOR • OpeRaTiOn and paRTs manuaL — Rev. #7 (02/28/14) — page 27

„

Check the battery regularly and make sure that each

electrolyte level is to the bottom of the vent well (Figure 35).

If necessary add only distilled water in a well-ventilated area.

Figure 35. Battery Electrolyte Levels

BaTTeRY ChaRging

„

dO nOT charge battery with the battery cables

connected to the compactor. The diodes will be damage

by the high voltage.

„

Batteries generate hydrogen gas which

can be highly explosive.

dO nOT smoke

or allow flames or sparks near the battery,

especially during charging of the battery.

„

Charge the battery in a open air environment (plenty of

ventilation).

„

Before charging , remove the cap from each cell of the

battery.

„

Connect the positive (+) lead of the charger to the

positive (+) terminal of the battery and the negative (-)

lead of the charger to the negative (-) terminal of the

battery.

dO nOT reverse the polarity when charging.

Reverse polarity will damage the charger rectifier or

the battery.

„

Battery fluid will be lost through continuous charging

and discharging.

„

Discontinue charging if the electrolyte temperature

exceeds 117° F (45° C).

MAINTENANCE

BaTTeRY CaBLe COnneCTiOn (Option)

1. Take off the battery cover by removing the M6 nuts that

secure the battery holder to the cover.

2. When removing battery cables, disconnect the ground

side (normally negative) first (Figure 36).

3. When installing battery cable connect the ground side

(normally negative) last.

Figure 36. Removing Battery Cover

NOTICE

During summer much more battery fluid is lost than in

winter. Before starting, check battery electrolyte levels

and replenish with distilled water to the upper mark on

the battery.

BATTERY COVER

BATTERY

+ TERMINAL

- TERMINAL