beautypg.com

Operation, Compaction sensor (mvh406 dscpas only), Normal compaction – Multiquip MVH406DSCP User Manual

Page 21: Normal compaction (compaction limit)

background image

mvh406dsz/dsCpas pLaTe COmpaCTOR • OpeRaTiOn and paRTs manuaL — Rev. #7 (02/28/14) — page 21

OpERATION

COmpaCTiOn sensOR (mvh406 dsCpas Only)

Compaction Analyzing System (COMPAS) is a system that

uses an acceleration sensor to show real-time soil stiffness

via LED's (light-emitting diode) turning on with each pass

of the compactor.
This COMPAS improves compaction work efficiency

because it can prevent an already properly compacted area

from being compacted more than necessary and identify

an area where more compaction is needed.
COMPAS also has a function to detect abnormalities such

as vibration trouble (insufficient vibration frequency), ground

trouble (soft soil) and other functional issues (Figure 21).

Figure 21. Compaction Sensor (COMPAS)

normal Compaction (

Compaction progression

)

COMPACTION PROGRESSION LED’S 1 THRU 8 ON

NORMAL OPERATION

(GREEN LED ON)

COMPACTION LIMIT

LED’S 1 THRU 8 ON

PLUS RED LED ON

SOIL PROBLEM,

GREEN, AND RED

LED’S ON

VIBRATION ABNORMALITY

(GREEN LED FLASHING)

NOTICE

COMPAS can only show progression of the soil stiffness

and is not meant to measure absolute soil density.

When using COMPAS always calculate appropriate soil

density by conducting proper testing such as plate load

test and dynamic load test to best compliment the LED

lighting progression with the actual measurement value.

NOTICE

Not all yellow status LEDs will turn on. The progression

of the yellow status LEDs depends on the type of

soil being compacted. If compacting gravel (stiff soil)

potentially all status LEDs will turn ON.
If compacting sand (soft soil), fewer status LED's will

turn ON. Remember

dO nOT over compact.

When the plate compactor is in idle mode the

green LED

will begin flashing and the

red LED will turn on. As the

engine RPM's are increased and compaction begins, the

green LED will stop flashing and turn on (solid). The red

LED will turn off and the #1

yellow LED will turn on. As

compaction progresses the number of yellow LEDs, 2 thru

8 will turn on (Figure 22).
The number of yellow status LEDs that will turn on is soil

dependent.

Figure 22. Compaction Progression

normal Compaction (Compaction Limit)

The compaction limit (Figure 23) is achieved when all the

yellow LED's 1 thru 8 including the red LED are all on,

depending on type of soil being compacted . At this point

the machine cannot compact any further. If the compaction

results are not satisfactory then check and make sure the

soil type, moisture content, lift and number of passes are

proper for this machine.

Figure 23. Compaction Limit

NORMAL OPERATION

(GREEN LED ON)

COMPACTION PROGRESSION LED’S 2 THRU 8 ON

INITIAL COMPACTION YELLOW LED#1 ON

DURING COMPACTION YELLOW

LED’S 1 THRU 8 ON

RED LED ON