MTS Hydraulic Service Manifold Model 293-12B User Manual
Page 47
![background image](/manuals/568003/47/background.png)
Warning
:
Do not replace the filter with residual hydraulic pressure in the system.
Residual pressure can cause unexpected, high-pressure fluid discharge and actuator motion.
This can result in personal injury or death or damage to equipment.
Ensure that the HPU output pressure is zero before you begin the replacement procedure.
Description
Item
Vent Plug
1
Bowl
2
O-ring Seal
3
Filter Element
4
Filter Indicator
5
Filter Head
6
1. Turn the HPU off or remove hydraulic pressure from the hydraulic input of the HSM.
Series 293 Hydraulic Service Manifold Product Information | 47