Adjusting the output pressure, Adjusting the output pressure 25, Adjusting the output – MTS Model 512-14 Hydraulic Power Unit User Manual
Page 25: Pressure

Adjusting the Output Pressure
512.14 Hydraulic Power Unit
Operation
25
Adjusting the Output Pressure
The HPU comes with its output pressure set at 21 MPa (3000 psi). Special testing
needs may require you to lower this pressure.
Do not set the output pressure higher than 21 MPa (3000 psi).
Setting the output pressure above 21 MPa (3,000 psi) can damage the pump
and its motor.
Set the output pressure no higher than 21 MPa (3000 psi).
Procedure
To adjust the output pressure:
1. Set the HPU’s output to HIGH PRESS. Put the HPU into a no-flow
condition (where no fluid is flowing to other hydraulic equipment).
2. Wait for the fluid to reach the operating temperature of 64 and 68ºC (147
and 155ºF).
3. Hold the setscrew with a 5/32–inch hex key. Loosen the locknut with a 9/
16–inch wrench.
Output Pressure
Adjustment
CAUTION
- Series 111 Accumulator (40 pages)
- Series 249G2 Swivels (34 pages)
- Series 201 Actuators (40 pages)
- Series 215 Rotary Actuator (68 pages)
- Series 242 Actuators (40 pages)
- Series 244 Actuators (68 pages)
- Series 247 Actuators (40 pages)
- Series 248 Actuators (46 pages)
- 709 Alignment System (158 pages)
- Series 609 Alignment Fixture (70 pages)
- 494 Controller Hardware FT 40 (344 pages)
- ReNew Technical Reference (50 pages)
- DCPD Measurement System (46 pages)
- Bionix EnviroBath (40 pages)
- FGW900 High-temperature Furnace (38 pages)
- Model 409.83 Temperature Controller (40 pages)
- Series 651 Environmental Chambers (30 pages)
- Series 653 High-Temperature Furnaces (38 pages)
- Series 658 Environmental Chamber (24 pages)
- Series FEC Environmental Chamber (48 pages)
- Model 685.53 Grip Control Module (24 pages)
- Series 685 Hydraulic Grip Supply (48 pages)
- Bend Fixture-10 kN (2 pages)
- Grip-Manual Bend Fixture-100 kN (2 pages)
- Grip-Manual Bollard-2 kN (2 pages)
- Grip-Manual Bollard-500 N (2 pages)
- Compression Platen-100 kN-100mm (2 pages)
- Compression Platen-100 kN-150mm (2 pages)
- Compression Platen-100 kN-200mm (2 pages)
- Compression Platen-20 kN (2 pages)
- Compression Platen-20 kN-100mm (2 pages)
- Compression Platen-20 kN-200mm (2 pages)
- Compression Platen-20 kN-SST (2 pages)
- Compression Platen-500 N FYC502A (2 pages)
- Compression Platen-500 N FYB502A (2 pages)
- Compression Platen-500 N-50mm (2 pages)
- Grip-Pneumatic Vise-Style-1 kN (2 pages)
- Pneumatic Bollard-500 N (2 pages)
- Scissor-Style-2 kN (2 pages)
- Scissor-Style-5 kN (2 pages)
- Screw-Style-5 kN (2 pages)
- Screw-Style-5 kN-SST (2 pages)
- Bend Fixture-1000 kN (2 pages)
- Bend Fixture-300 kN (2 pages)
- Bolt Grips (32 pages)