Specifications, Specifications 10 – MTS Model 512-14 Hydraulic Power Unit User Manual
Page 10

512.14 Hydraulic Power Unit
10
Specifications
Introduction
Specifications
Parameter
Specification
Environmental
Operating temperature
(ambient air)
Heat load
*
Noise rating
†
at 1 m
18–40°C (65–104°F)
1061 kcal/hr (4200 BTU/hr)
74 dB (A)
Pump
Flow capacity
Motor rating
Operating voltage
12.5 lpm (3.3 gpm) @ 50 Hz
15.1 lpm (4 gpm) @ 60 Hz
5.6 kW (7.5 hp)
208 V (AC) @ 24.2 A, 3 phase
230 V (AC) @ 22.0 A, 3 phase
460 V (AC) @ 11.0 A, 3 phase
Hydraulic fluid
Nominal temperature
Filtration (microns)
Reservoir capacity
Maximum pressure
Mobil DTE 25
®
or Shell Tellus
®
46 AW
63°C (145°F)
3 microns absolute
57 liters (15 gallons)
20.7 MPa (3000 psi)
Heat exchanger
Flow requirements
Water pressure
(differential)
Max input pressure
Cooling
Water hose
Water cooled or air cooled
13 lpm @ 21°C (3.5 gpm @ 70°F)
0.2 MPa (30 psi)
1 MPa (150 psi)
4892 Kcal/hr (19,410 BTU/hr)
12.7 mm (0.5 in)—inside diameter
Hydraulic connections
Pressure
Return
Drain
each requires a 37° flare
-8
-8
-6
Weight
115 kg (250 lb)
*
Specification is for 60 Hz operation.
†
Free field value [74 db. Your readings may be up to 10 db (A) more.
- Series 111 Accumulator (40 pages)
- Series 249G2 Swivels (34 pages)
- Series 201 Actuators (40 pages)
- Series 215 Rotary Actuator (68 pages)
- Series 242 Actuators (40 pages)
- Series 244 Actuators (68 pages)
- Series 247 Actuators (40 pages)
- Series 248 Actuators (46 pages)
- 709 Alignment System (158 pages)
- Series 609 Alignment Fixture (70 pages)
- 494 Controller Hardware FT 40 (344 pages)
- ReNew Technical Reference (50 pages)
- DCPD Measurement System (46 pages)
- Bionix EnviroBath (40 pages)
- FGW900 High-temperature Furnace (38 pages)
- Model 409.83 Temperature Controller (40 pages)
- Series 651 Environmental Chambers (30 pages)
- Series 653 High-Temperature Furnaces (38 pages)
- Series 658 Environmental Chamber (24 pages)
- Series FEC Environmental Chamber (48 pages)
- Model 685.53 Grip Control Module (24 pages)
- Series 685 Hydraulic Grip Supply (48 pages)
- Bend Fixture-10 kN (2 pages)
- Grip-Manual Bend Fixture-100 kN (2 pages)
- Grip-Manual Bollard-2 kN (2 pages)
- Grip-Manual Bollard-500 N (2 pages)
- Compression Platen-100 kN-100mm (2 pages)
- Compression Platen-100 kN-150mm (2 pages)
- Compression Platen-100 kN-200mm (2 pages)
- Compression Platen-20 kN (2 pages)
- Compression Platen-20 kN-100mm (2 pages)
- Compression Platen-20 kN-200mm (2 pages)
- Compression Platen-20 kN-SST (2 pages)
- Compression Platen-500 N FYC502A (2 pages)
- Compression Platen-500 N FYB502A (2 pages)
- Compression Platen-500 N-50mm (2 pages)
- Grip-Pneumatic Vise-Style-1 kN (2 pages)
- Pneumatic Bollard-500 N (2 pages)
- Scissor-Style-2 kN (2 pages)
- Scissor-Style-5 kN (2 pages)
- Screw-Style-5 kN (2 pages)
- Screw-Style-5 kN-SST (2 pages)
- Bend Fixture-1000 kN (2 pages)
- Bend Fixture-300 kN (2 pages)
- Bolt Grips (32 pages)