Final Assembly

Electrical Requirements

Grounding

EXTENSION CORDS

Plug the cord from the motor into the upper outlet on the meter box (the one opposite the motor on-off

switch). The other outlet on the meter box is for use with the vacuum pump.

The MK-Manta III Core Drill rig has been equipped with a Milwaukee motor. The drill should be used

on an electrical circuit, separate from other loads, and protected by a 30 amp circuit breaker. the MK-

Manta III Core Drill has been provided with a 20 Amp plug (NEMA 15-20) or a 30 Amp (NEMA 15-30)

locking plug depending on the model.

The MK-Manta III Core Drill is marked “Grounding Required” and has a three wire cord and three

prong grounding plug. The plug must be connected to a properly grounded outlet (see figure below).

If the tool should electrically malfunction or break down, grounding provides a low resistance path to

carry electricity away from the user, reducing the risk of electrical shock.
The grounding prong in the plug is connected through the green wire inside the cord to the grounding

system in the tool. The green wire in the cord must be the only wire connected to the toll’s grounding

systems and must never be attached to an electrically live terminal.
Your tool must be plugged into an appropriate outlet, properly installed and grounded in accordance

with all codes and ordinances.

Do not use the tool if the cord or plug is damaged. IF damaged, have it repaired by an authorized

service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified

electrician. The use of a circuit protected by a ground fault interrupter (GFCI) is highly recommended.
Use extension cords of the proper cable size, referring to the following chart.

DRILLING OPERATIONS

Improperly connecting the grounding wire can result in the risk of elec-

tric shock. Check with a qualified electrician if you are in doubt as to

whether the outlet is properly grounded. Do not modify the plug pro-

vided with the tool. Never remove the grounding prong from the plug.

WARNING

EXTENSION CORD MINIMUM GAGE FOR LENGTH

TOTAL LENGTH OF CORD IN FEET

Cord Length

25 ft. AWG

50 ft. AWG

75 ft. AWG

Wire Size (AWG)

#10

#8

#6

MANTA CORE DRILL III