Maintenance and troubleshooting – MK Diamond MK-145 220 Volt User Manual
Page 24
MK Diamond Products Inc. Customer Service Department (800) 421-5830
MK-145
Revision 09/04, Effective date – September 23, 2004
Page
24
MAINTENANCE and TROUBLESHOOTING:
Diamond Blade Change-out:
STEP ACTION
1.
Unplug the MK-145
a) Unplug the MK-145 from the power source
b) Unplug the MK-145 from the GCFI
2.
Remove Retaining Nut and Outer Flange
a) Hold the Diamond Blade still
b) Rotate the Blade Wrench counter-clockwise to
loosen
c) Remove the Retaining Nut and Outer Flange
3.
Remove the Diamond Blade
a) Remove the Blade out from between the Table
Blade Slot from below
4.
Install Diamond Blade
a) Orient the Blade to the Gear Shaft with the
Directional Arrow facing out
b) Install the Blade through the Table Blade Slot
from below
5.
Verify Blade Seated
a) Verify the Blade is seated on the Gear Shaft
b) Verify Blade Directional Arrow matches the
Directional Arrow on the Blade Guard
NOTE: Do not “cross-thread the Retaining Nut during installation.
6.
Install The Retaining Nut and Outer Flange
a) Install the Plastic Outer Flange onto the Gear
Shaft
b) Install the Retaining Nut onto the Gear Shaft
7. Tightening
Diamond
Blade
a) Hold the Diamond Blade still
b) Rotate the Blade Wrench clockwise to tighten –
DO NOT OVER TIGHTEN
8.
Reinstall the Water Basin Cover
a) Insert the three (3) Cover Retaining Tabs into
the three (3) Cover Alignment Slots
b) Seat the Water Basin Cover on the MK-145
Blade Slot
Diamond Blade
Installed on
Gear Shaft
Directional
Arrow
GFCI
Rotate to
loosen
Blade
Wrench
Blade Slot
Diamond Blade
Alignment
Slot
Retaining Tab
Retaining nut
Rotate to
tighten
Blade
Wrench
Outer Flange