V-line 32 – Metal Sales V-Line 32 User Manual
Page 7

PVL-7
V-LINE 32
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
s
eCTion
P
roPerTies
and
g
eneral
i
nformaTion
C
32" Coverage
1
3
/
8
"
7
/
8
"
3
5
/
8
"
4
9
/
16
"
1. Theoretical section properties have been calculated per AISI 2001 “Specification for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are
effective section properties for deflection and bending.
2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear, deflection. Allowable load
considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or
fasteners/support connection and panel weight is not considered.
3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.
4. Allowable loads do not include a 1/3 stress increase in uplift.
ALLOWABLE UNIFORM LOADS PSF
(3 or More Equal Spans)
5’ 6’ 7’ 8’ 9’ 10’ 5’ 6’ 7’ 8’ 9’ 10’
SECTION PROPERTIES
Bottom in Compression
Width
(in.)
Yield
KSI
32”
60
32”
50
32”
50
26
Ga.
24
22
Sxx
In
3
/ft
Ixx
In
4
/ft
Weight
PSF
0.91
1.20
1.57
Top in Compression
Sxx
In
3
/ft
Ixx
In
4
/ft
Inward
Load
Outward
Load
0.0619 0.0847 0.0619 0.0833
70 52 33 22 16 11 71 53 33 22 16 11
0.0870
0.1217
0.0874
0.1209 102 70 44 29 21 15 103 70 44 29 21 15
0.1163
0.1623
0.1200
0.1683 147 92 58 39 27 20 143 92 58 39 27 20
Slope
Substructure
Coverage
Length
Fasteners
Availability
GENERAL INFORMATION
ATTACHMENT DETAIL
FASTENING PATTERN
The minimum recommended slope for V-Line 32 roofing
panel is 1:12. Metal Sales recommends that in all roof
applications sealants be used on all sidelaps with a stitch
screw 1'-0" on center
V-Line 32 is designed to be utilized over open structural
framing or a solid substrate. To avoid panel distortion use a
properly aligned and uniform substructure.
V-Line 32 is available in 1 3/8" rib height with a coverage
width of 32".
Minimum factory cut length is 5'-0". Maximum
recommended panel length is 45'-0". Longer panels
require additional consideration in packaging, shipping, and
erection. Please consult Metal Sales for recommendations.
The fastener selection guide should be consulted for
choosing the proper fastener for specific applications.
Quantity and type of fastener must meet necessary loading
and code requirements.
NOTE: All panels are subject to surface distortion due to
improperly applied fasteners. Overdriven fasteners will
cause stress and induce oil canning across the face of the
panel at or near the point of attachment.
Finishes: Acrylic Coated Galvalume
®
, MS Colorfast45
®
, or
various Kynar 500 (PVDF) colors.
Gauges: 24 ga, 26 ga standard and 22 ga optional.
Tape Sealant
1
/
4
"-14 x
7
/
8
" Stitch Screw
(for roof only)
#9-15 x 1" Woodscrew
Tape Sealant
1
/
4
"-14 x
7
/
8
" Stitch Screw
(for roof only)
#9-15 x 1" Woodscrew