V-line 32, Ul-580 w – Metal Sales V-Line 32 User Manual
Page 6
PVL-6
V-LINE 32
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
1. Metal Roof Deck Panels* No. 26 MSG min gauge, coated steel. Panels continuous over two or more spans. End laps to occur
over purlins with panels overlapped 6 in. with lap beginning 1 in. from purlin web and extending across purlin upper flange. A
line of mastic sealant may be used at panel end and side laps.
METAL SALES MFG CORP
2. Panel Fasteners Fasteners for panel-to-purlin and panel-to-panel connections to be No. 12-14 by 1 in. long self-drilling, self-
tapping, hex-head, coated steel screws with 5/8 in. diam coated steel with bonded neoprene washers.
Spacing to be approximately 9 in. O.C. located in every other panel valley with a fastener located on both sides of the side
lapped rib.
Spacing at the end laps to be the same.
Alternate fastener for panel-to-panel connections; No. 14 by 3/4 in. long self-drilling, self-tapping, hex-head, coated steel
screws with 5/8 in. diam coated steel, bonded neoprene washers may be used. Spacing to be 15 in. O.C.
3. Insulation (Optional) - Any compressible blanket insulation, 4 in. max thickness before compression.
4. Purlins No. 16 MSG min gauge steel (55,000 PSI min yield strength).
5. Lateral Bracing (Not shown) - As required.
Refer to General Information, Roof Deck Constructions (Roofing Materials and Systems Directory) for items not evaluated.
*Bearing the UL Classification Marking
Ul-580 w
ind
U
PlifT
i
nformaTion
Construction No. 187
October 09, 1997
Metal Deck Assemblies
Uplift - Class 90
Fire Not Investigated
V-LINE 32
Underwriters Laboratories Inc.
®
UL
®
LISTED
1
1
1
2
2
2
3
3
3
3
4
4
60.25" Max.