V-line 32 – Metal Sales V-Line 32 User Manual
Page 2
PVL-2
V-LINE 32
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
P
anel
o
verview
PANEL PROFILE
SLOPE
SUBSTRATE
COVERAGE
LENGTH
AVAILABILITY
APPLICATION
FASTENING SYSTEM
FASTENERS
MATERIALS
FINISH
The minimum recommended slope for any V-Line 32 Panel roofing panel is 1:12.
V-Line 32 panel is designed to be utilized over open structural framing, but can easily be used wth a solid
substrate. For solid substrate applications, the recommended substrate is
5
/
8
" plywood with a 30 pound felt
moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure.
V-Line 32 Panel has a coverage of 32" with a 1
3
/
8
" Rib Height.
Lengths under 5'-0" are available with some cutting restrictions. Maximum recommended panel length is 45'-
0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult your
Metal Sales branch for recommendations (see PGI-2 and 3 for locations).
26, 24, and 22 Gauge. Minimum quantities may apply.
Commercial, Industrial panel.
Direct fastened (exposed).
The fastener selection guide should be consulted for choosing proper fasteners for specific applications.
Quantity and type of fastener must meet necessary loading and code requirements (see PGI-12-14). Note: All
panels are subject to surface distortion due to improperly applied fasteners. Over driven fasteners will cause
stress and induce oil-canning across the face of the panel at or near the point of attachment.
Steel grade 80 for 26 Gauge and grade 50 for 22 and 24 Gauge, per ASTM A-792
*
Acrylic Coated Galvalume
®
(ACG) / ASTM A-792 - AZ55
Prepainted Galvalume / ASTM A-792 - AZ50
**
Fluorocarbon (PVDF)
*
Differential appearance of Acrylic Coated Galvalume roofing materials is not a cause for rejection.
**
Meets both Kynar 500 and Hylar 5000 specifications.
C
32" Coverage
1
3
/
8
"
7
/
8
"
3
5
/
8
"
4
9
/
16
"
PERFORMANCE TEST
UL 580, UL 2218, UL 790, Texas Department of Insurance