T10-c s – Metal Sales T10-C User Manual
Page 7

PV-7
V
erti
-L
ine
S
erieS
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
T10-C s
eCTion
P
roPerTies
and
g
eneral
i
nformaTion
C
30" Coverage
5
/
8
"
6" Pitch
1
1
/
4
"
4
3
/
4
"
1
1
/
2
"
ALLOWABLE UNIFORM LOADS PSF
(3 or More Equal Spans)
5’ 6’ 7’ 8’ 10’ 12’ 5’ 6’ 7’ 8’ 10’ 12’
SECTION PROPERTIES
Bottom in Compression
Width
(in.)
Yield
KSI
30”
50
30”
50
30”
33
30”
33
24
Ga.
22
20
18
Sxx
In
3
/ft
Ixx
In
4
/ft
Weight
PSF
1.36
1.80
2.13
2.80
Top in Compression
Sxx
In
3
/ft
Ixx
In
4
/ft
0.0840
0.1075
0.1252
0.1190 110 77 56 43 23 13 99 69 51 39 23 13
0.1204
0.1578
0.1752
0.1696 156 109 80 59 30 18 146 101 75 57 30 18
0.1640
0.1949
0.2120
0.2058 125 87 64 49 32 21 118 83 61 47 30 21
0.2400
0.2606
0.2760
0.2687 163 114 84 64 41 26 158 110 81 62 40 26
Inward
Load
Outward
Load
1. Theoretical section properties have been calculated per AISI 2001. “Specifications for the Design of Cold-formed Steel Structural
Members.” Ixx and Sxx are effective section properties for deflection and bending.
2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear and
deflection. Allowable load considers both 3 and 4 equal span conditions. Allowable load does not address web crippling or
fasteners/support connection. Panel weight is not considered.
3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.
4. Allowable loads do not include a 1/3 stress increase in uplift.
Substructure
Coverage
Length
Fasteners
Availability
GENERAL INFORMATION
T10-C Panels are designed to be utilized over open
structural framing or a solid substrate.
T10-C Panels are available in a 1
1
/
2
" depth with a coverage
width of 30".
Minimum factory cut length is 5'-0".
Maximum available panel length is 32'-0".
The fastener selection guide should be consulted for
choosing the proper fastener for specific applications.
Quantity and type of fastener must meet necessary
loading and code requirements.
NOTE: All panels are subject to surface distortion due to
improperly applied fasteners. Overdriven fasteners will
cause stress and induce oil canning across the face of the
panel at or near the point of attachment.
Finishes: Kynar 500 (PVDF) standard;
optional: multi-pass Kynar, Marblique, Plastisol, Polyester,
and MS Colorfast45
®
(SMP)
Gauges: 24ga, 22ga, 20ga and 18ga
#12-14 Self Driller
#12-14 Self Driller
#12-14 Self Driller
FASTENING PATTERNS
ATTACHMENT DETAIL
Ends of Panel
Field of Panel