T10-a s – Metal Sales T10-C User Manual
Page 6
PV-6
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
V
erti
-L
ine
S
erieS
T10-a s
eCTion
P
roPerTies
and
g
eneral
i
nformaTion
C
28" Coverage
5
/
8
"
1
1
/
2
"
4" Pitch
1
1
/
4
"
2
3
/
4
"
ALLOWABLE UNIFORM LOADS PSF
(3 or More Equal Spans)
5’ 6’ 7’ 8’ 10’ 12’ 5’ 6’ 7’ 8’ 10’ 12’
SECTION PROPERTIES
Bottom in Compression
Width
(in.)
Yield
KSI
28”
50
28”
50
28”
33
28”
33
24
Ga.
22
20
18
Sxx
In
3
/ft
Ixx
In
4
/ft
Weight
PSF
1.60
2.10
2.52
3.32
Top in Compression
Sxx
In
3
/ft
Ixx
In
4
/ft
0.1221
0.1569
0.1539
0.1657 153 107 79 54 28 16 145 101 74 54 28 16
0.1736
0.2275
0.2130
0.2358 217 152 106 71 36 21 210 146 106 71 36 21
0.2314
0.2790
0.2529
0.2835 172 120 89 68 42 25 170 118 87 67 42 25
0.3257
0.3699
0.3300
0.3686 224 156 115 88 54 31 225 157 116 89 54 31
Inward
Load
Outward
Load
1. Theoretical section properties have been calculated per AISI 2001. “Specifications for the Design of Cold-formed Steel Structural
Members.” Ixx and Sxx are effective section properties for deflection and bending.
2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear and
deflection. Allowable load considers both 3 and 4 equal span conditions. Allowable load does not address web crippling or
fasteners/support connection. Panel weight is not considered.
3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.
4. Allowable loads do not include a 1/3 stress increase in uplift.
Substructure
Coverage
Length
Fasteners
Availability
GENERAL INFORMATION
T10-A Panels are designed to be utilized over open
structural framing or a solid substrate.
T10-A Panels are available in a 1
1
/
2
" depth with a coverage
width of 28".
Minimum factory cut length is 5'-0".
Maximum available panel length is 32'-0".
The fastener selection guide should be consulted for
choosing the proper fastener for specific applications.
Quantity and type of fastener must meet necessary
loading and code requirements.
NOTE: All panels are subject to surface distortion due to
improperly applied fasteners. Overdriven fasteners will
cause stress and induce oil canning across the face of the
panel at or near the point of attachment.
Finishes: Kynar 500 (PVDF) standard;
optional: multi-pass Kynar, Marblique, Plastisol, Polyester,
and MS Colorfast45
®
(SMP)
Gauges: 24ga, 22ga, 20ga and 18ga
#12-14 Self Driller
#12-14 Self Driller
#12-14 Self Driller
FASTENING PATTERNS
ATTACHMENT DETAIL
Ends of Panel
Field of Panel