Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting
problems of moisture damage and loss of insulation efficiency.
Condensation occurs when moisture laden air comes in contact with a surface temperature equal to or below the dew point
of the air. This phenomenon creates problems that are not unique with metal roofing; these problems are common to all types
of construction.
The underside of the metal roof on a typical Architectural building should be protected from condensation by installing
panels directly over a minimum 30 lb moisture barrier and uniform solid substrate. This reduces airspace and the potential of
condensation forming on the underside of the panels.
VENTILATION
Typical metal building (no attic)
Vent
Vent at wall
Vent at eave
Building with attic or retrofitted
Vent
Insulation
PANEL APPLICATIONS
The following chart highlights UL 580 #435 for fastener spacing on the selected applications (see Fastener Selection Guide
pages PGI-12-14 for other fasteners available). For more information on UL Construction numbers, refer to UL Roofing Materials
and System Directories.
* ABMP XL Fastener also available in
1
/
4
"-14 x 1" - Painted.
** Based on UL-580, subject to project loading, closer fastener spacing may be required. Contact your local Metal Sales
branch representative for more information (see pages PGI2 - PGI3).
NUMBER
REQUIRED
TYPE OF FASTENER
APPLICATION
INSTALLATION
REQUIREMENTS
FASTENER
SPACING
PANEL TYPE
9-15 x 1" ABMP XL - PAINTED
4 FASTENERS*
26 GAUGE
3'-0" O.C.**
FASTENERS OVER
5
/
8
" PLYWOOD DECK
CONST. #435
UL-90
5V-Crimp