beautypg.com

5v-crimp – Metal Sales 5V-Crimp User Manual

Page 8

background image

P5V-8

5V-CRIMP

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

d

esign

/ i

nsTallaTion

C

onsideraTions

(

ConT

.)

Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting

problems of moisture damage and loss of insulation efficiency.

Condensation occurs when moisture laden air comes in contact with a surface temperature equal to or below the dew point

of the air. This phenomenon creates problems that are not unique with metal roofing; these problems are common to all types

of construction.

The underside of the metal roof on a typical Architectural building should be protected from condensation by installing

panels directly over a minimum 30 lb moisture barrier and uniform solid substrate. This reduces airspace and the potential of

condensation forming on the underside of the panels.

VENTILATION

Typical metal building (no attic)

Vent

Vent at wall

Vent at eave

Building with attic or retrofitted

Vent

Insulation

PANEL APPLICATIONS

The following chart highlights UL 580 #435 for fastener spacing on the selected applications (see Fastener Selection Guide

pages PGI-12-14 for other fasteners available). For more information on UL Construction numbers, refer to UL Roofing Materials

and System Directories.

* ABMP XL Fastener also available in

1

/

4

"-14 x 1" - Painted.

** Based on UL-580, subject to project loading, closer fastener spacing may be required. Contact your local Metal Sales

branch representative for more information (see pages PGI2 - PGI3).

NUMBER

REQUIRED

TYPE OF FASTENER

APPLICATION

INSTALLATION

REQUIREMENTS

FASTENER

SPACING

PANEL TYPE

9-15 x 1" ABMP XL - PAINTED

4 FASTENERS*

26 GAUGE

3'-0" O.C.**

FASTENERS OVER

5

/

8

" PLYWOOD DECK

CONST. #435

UL-90

5V-Crimp