P5V-2

5V-CRIMP

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

P

anel

o

verview

PANEL PROFILE

SLOPE

SUBSTRATE

COVERAGE

LENGTH

AVAILABILITY

APPLICATION

FASTENING SYSTEM

FASTENERS

MATERIALS

FINISH

The minimum recommended slope for any 5V-Crimp roofing panel is 3:12.

The recommended substrate is

5

/

8

" plywood with a 30 pound felt moisture barrier. To avoid panel distortion,

use a properly aligned and uniform substructure. Please note that 5V-Crimp panels are not recommended

for use over open framing.

5V-Crimp is available in 24" width with a

1

/

2

" rib height.

Lengths under 5'-0" are available with some cutting restrictions. Maximum recommended panel length is 45'-

0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult your

Metal Sales branch for recommendations (see PGI-2 and 3 for locations).

26 Gauge

Architectural and Residential panel.

Direct fastened (exposed).

The fastener selection guide should be consulted for choosing proper fasteners for specific applications.

Quantity and type of fastener must meet necessary loading and code requirements (see PGI-12-14).

PERFORMANCE TEST

UL 580, UL 790, UL 263, UL 2218, Miami-Dade County

Steel grade 50, per ASTM A-792

*

Acrylic Coated Galvalume

®

(ACG) / ASTM A-792 - AZ55

Prepainted Galvalume / ASTM A-792 - AZ50

**

Fluorocarbon (PVDF)

*

Differential appearance of Acrylic Coated Galvalume roofing materials is not a cause for rejection.

**

Meets both Kynar 500 and Hylar 5000 specifications.

12"

1

/

2

"

C

24" Coverage