5v-crimp – Metal Sales 5V-Crimp User Manual
Page 2
![background image](/manuals/567677/2/background.png)
P5V-2
5V-CRIMP
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
P
anel
o
verview
PANEL PROFILE
SLOPE
SUBSTRATE
COVERAGE
LENGTH
AVAILABILITY
APPLICATION
FASTENING SYSTEM
FASTENERS
MATERIALS
FINISH
The minimum recommended slope for any 5V-Crimp roofing panel is 3:12.
The recommended substrate is
5
/
8
" plywood with a 30 pound felt moisture barrier. To avoid panel distortion,
use a properly aligned and uniform substructure. Please note that 5V-Crimp panels are not recommended
for use over open framing.
5V-Crimp is available in 24" width with a
1
/
2
" rib height.
Lengths under 5'-0" are available with some cutting restrictions. Maximum recommended panel length is 45'-
0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult your
Metal Sales branch for recommendations (see PGI-2 and 3 for locations).
26 Gauge
Architectural and Residential panel.
Direct fastened (exposed).
The fastener selection guide should be consulted for choosing proper fasteners for specific applications.
Quantity and type of fastener must meet necessary loading and code requirements (see PGI-12-14).
PERFORMANCE TEST
UL 580, UL 790, UL 263, UL 2218, Miami-Dade County
Steel grade 50, per ASTM A-792
*
Acrylic Coated Galvalume
®
(ACG) / ASTM A-792 - AZ55
Prepainted Galvalume / ASTM A-792 - AZ50
**
Fluorocarbon (PVDF)
*
Differential appearance of Acrylic Coated Galvalume roofing materials is not a cause for rejection.
**
Meets both Kynar 500 and Hylar 5000 specifications.
12"
1
/
2
"
C
24" Coverage