1. Metal Roof Deck Panels* No. 26 MSG minimum coated steel. Maximum panel width 24 in. Rib height maximum 1/2 in. Panels

continuous over two or more spans. A bead of sealant may be used at panel sidelaps.

METAL SALES MFG CORP - “5V Crimp”

2. Fasteners - (Screws) For panel attachment to wood deck (Item 3), fasteners to be #9-15 x 1 in. Type A, Hex-head with separate

5/8 in. OD steel washer and a bonded neoprene washer. Fastener spacing is as follows: a line of fasteners is to be installed, beginning

from the center of the double V at the sidlap in 2-9-2-9 in. pattern for a total of four fasteners across the width of the panel. This

fastener spacing to be 3 feet on center along the length of the panel is 3 feet on center.

For attachment of plywood deck (Item 3) to joists (Item 5), fasteners to be minimum No. 6 x 1-7/8 in. bugle head screw or annular

ring-shank nails. Spacing to be 6 in. OC at plywood edges and 12 in. OC at intermediate supports.

When light gauge structural steel joists are used, fasteners to be No. 12 x 1-5/8 in. long with a Phillips head.

3. Substructure - (Plywood) Plywood decking to be a nom 5/8 in. thick, exposure sheathing span C-D, 40/20 plywood. All butt joints to

be sealed against leakage by using tape and/or caulk or with one-part urethane sealant.

4. Moisture Barrier (Optional) Any suitable membrane to protect substructure (Item 3).

5. Joists Joists spaced at 2 ft , 0 in. OC; may be one of the following:

A. Nom 2 by 6 in. wood joists No. 2 or better.

B. Nom 2 by 4 in. wood when used on a top cord of a wood truss, No. 2 or better.

C. Light gauge structural steel framing with the member against the plywood to be a minimum No. 22 MSG coated steel.

Refer to General Information, Roof Deck Construction, (Roofing Materials and Systems Directory) for Items Not Evaluated.

*Bearing the UL Classification Mark

Construction No. 453

March 13, 2001

Uplift - Class 90

Fire Not Investigated