beautypg.com

5v-crimp – Metal Sales 5V-Crimp User Manual

Page 6

background image

P5V-6

5V-CRIMP

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

s

eCTion

P

roPerTies

and

g

eneral

i

nforMaTion

ALLOWABLE UNIFORM LOADS PSF

(3 or More Equal Spans)

0'-6"

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

24"

50

26

Ga.

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

0.77

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

0.0025 0.0069 0.0015 0.0054

Outward Uplift Load

1'-0"

1'-6"

2'-0"

2'-6"

3'-0"

101

89

60

34

22

15

24"

50

24

1.02 0.0030 0.0089 0.0020 0.0073

101

89

60

34

22

15

1. Theoretical section properties have been calculated per AISI 2001. “Specifications for the Design of Cold-formed Steel Structural

Members.” Ixx and Sxx are effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear and

deflection. Allowable load considers both 3 or more equal span conditions. Allowable load does not address web crippling or

fasteners/support connection. Panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase in uplift.

12"

1

/

2

"

C

24" Coverage

#9-15x2" Woodscrew

Slope

Substructure

Coverage

Length

Fasteners

Availability

GENERAL INFORMATION

ATTACHMENT DETAIL

FASTENING PATTERNS

The minimum recommended slope for 5V-Crimp roofing

panel is 3:12.

*Contact Metal Sales Technical Services for Miami-Dade County attachment requirements.

#9-15x2" Woodscrew

#9-15x2" Woodscrew

Field of Panel

Ends of Panel

The recommended substrate is

5

/

8

" plywood with a 30

pound felt moisture barrier. To avoid panel distortion use

a properly aligned and uniform substructure.

NOTE: 5V-Crimp roof panels are not recommended for

use over open structural framing.

Minimum factory cut length is 5'-0". Maximum

recommended panel length is 45'-0". Longer panels

require additional consideration in packaging, shipping, and

erection. Please consult Metal Sales for recommendations.

The fastener selection guide should be consulted for

choosing the proper fastener for specific applications.

Quantity and type of fastener must meet necessary loading

and code requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of the

panel at or near the point of attachment.

Finishes: Acrylic Coated Galvalume

®

and MS Color-

fast45

®

Gauges: 26ga and 24ga

5V-Crimp panels are available in a

1

/

2

" rib height with a

coverage width of 24".